Select 001, press enter – the logger will automatically start scanning for all
the probe listed in profile 001. (The probe wakes up every 15 seconds to
“listen” if any logger or device is polling it.)
On the logger screen (LCD) the signal strength is displayed as well as the
remaining seconds. Once the logger makes a connection to the probe, the
signal strength and remaining number of logs are displayed and the logger
starts downloading the logs.
Upon completion the logger LCD will display “Download Completed”.
10.2.2 Single Log
To download all the readings from a specific probe:
How to:
Browse to Single Log option by scrolling through the menu button.
Select probe ID by entering the applicable probe ID i.e. 5177
Press enter.
Logger will start scanning for this probe.
Once the logger has made a successful connection, it will start retrieving
all the available data on that specific probe.
All the available data from this probe will be downloaded.
11 Add-on’s
The AquaCheck probe offers plug & play options for a rain gauge and or a
dendrometer (PlantSense
TM
). To add a rain gauge, the default battery pack and
probe head needs to be replaced with the appropriate components. Please contact
your local AquaCheck distributor or visit our website at
www.aquacheck.co.za
for
more detail.
12 Maintenance
Very little maintenance is required when using the AquaCheck probe. The only
replaceable part is the battery pack. The battery pack should last for up to 18
months under normal conditions. To replace the battery, remove the probe head and
disconnect the old battery pack from the battery board. Make sure the battery board
is properly seated in the 14-pin connector before connecting the new battery.
Remember to set the time and date again after replacing the battery.