Page - 34
ERROR AT MASTER UNIT
ISSUE
The heat pump is slaved to a master heat pump that is displaying a fault code.
RESOLUTION
The error at the master heat pump must be corrected before the slaved unit will resume operation.
HIGH PRESSURE FAULT
ISSUE
The refrigerant system’s high-pressure switch is showing as open.
RESOLUTION
Heat and Cool Units (Reversing)
Place heat pump in heating mode and perform the following troubleshooting.
Determine if an insufficient amount of water is being supplied to the equipment.
1. Confirm the filter pump is on.
2. If a multiple-speed filter pump is being used, run filter pump at a higher speed. Do not exceed
maximum flow rate for the model.
3. Confirm water is not being diverted away from the heat pump.
l
See "Water Flow Rates" on page 28.
l
See "Adjusting Water Flow Using ΔT (Delta-T)" on page 29.
HIGH WATER TEMPERATURE
ISSUE
Incoming water temperature has exceeded 110° F (43° C) and the unit has been deactivated. The heat
pump will not operate until incoming water temperature drops to 100° F (38° C) or lower.
RESOLUTION
1. Determine if a gas heater is sending water directly to the heat pump. This situation would need to be
corrected before continuing.
2. If a solar heater is sending water directly to the heat pump, the water can initially be hotter than 110° F (43°
C). After the water from the solar panel normalizes, the fault will no longer display and the heat pump will
resume as needed.
3. If the
HIGH WATER TEMPERATURE
fault continues to display, the water temperature sensor may
require replacement.
HP5 SYSTEM LOCKOUT
ISSUE
The heat pump has locked due to five high-pressure faults during one call for heating or cooling.
RESOLUTION
1. Deactivate then reactivate power to the heat pump to clear error.
2. Troubleshoot the high-pressure issue causing the error.
l
See "HIGH PRESSURE FAULT" on page 34.
3
-
T
roubl
es
hoot
ing
Содержание GBB BB500
Страница 2: ......
Страница 12: ...Page 9 1 5 c Setting Date and Time Set the heat pump s time and date using the following steps 1 Operation...
Страница 14: ...Page 11 Customize Date The date can be displayed as Day Month Year the default is Month Day Year 1 Operation...
Страница 15: ...Page 12 1 Operation...
Страница 17: ...Page 14 1 Operation...
Страница 21: ...Page 18 Configure for Flex mode 1 Operation...
Страница 24: ...Page 21 1 Operation...
Страница 26: ...Page 23 1 Operation...
Страница 50: ......
Страница 51: ......