2 - Maintenance
IN THIS SECTION:
2.4 Irrigation and Storm Run-Off
2.6 Adjusting Water Flow Using ΔT (Delta-T)
2.1 Water Chemistry
Check water chemistry regularly and maintain within recommended levels. Standards vary in different
residential and commercial applications. Follow all local applicable codes.
NOTICE
Failure to heed the following may result in damage to equipment.
l
Do not allow water to flow through heat pump when refinishing or acid washing a pool. Either use an installed
bypass to route water away from heat pump or deactivate filter pump.
l
To avoid damage to equipment, monitor and maintain chemistry within recommended levels.
CHEMISTRY LEVEL CHART
(RESIDENTIAL)
CHEMICAL
POOLS
SPAS
Chlorine
1.0 – 3.0 ppm
3.0 – 5.0 ppm
Bromine
2.0 – 6.0 ppm
2.0 – 6.0 ppm
Cyanuric
Acid
30 – 50 ppm
30 – 50 ppm
pH
7.4 – 7.6
7.4 – 7.6
Total
Alkalinity
80 – 120 ppm
80 – 120 ppm
Calcium
Hardness
200 – 400 ppm
150 – 250 ppm
Total
Dissolved
Solids
*
0 – 1,500 ppm
1,500 ppm above start-up of total
dissolved solids in spas
*
Salt from a chlorine generator is not included in Total Dissolved Solids.
2
-
M
ai
nt
ena
nc
e
Содержание GBB BB500
Страница 2: ......
Страница 12: ...Page 9 1 5 c Setting Date and Time Set the heat pump s time and date using the following steps 1 Operation...
Страница 14: ...Page 11 Customize Date The date can be displayed as Day Month Year the default is Month Day Year 1 Operation...
Страница 15: ...Page 12 1 Operation...
Страница 17: ...Page 14 1 Operation...
Страница 21: ...Page 18 Configure for Flex mode 1 Operation...
Страница 24: ...Page 21 1 Operation...
Страница 26: ...Page 23 1 Operation...
Страница 50: ......
Страница 51: ......