Using your
UA 2 aquaBUBBLER
At times the water flow may fluctuate depending
on your local water supply pressure. Re-adjusting
is simple using a 6mm flat head screw driver.
Read water meter via slot
Adjusting water flow
Adjust Water Flow
Dome Head Bolt
One hundred twenty three thousand
four hundred and fifty six litres
Trouble Shooting
Water Meter Slot
Water flow will need adjusting 1-2 days after installation
What to do if the UA 2 aquaBUBBLER becomes blocked?
You will need to unblock the S-Trap.
This means removing the stainless steel (S/S) dish.
Use the security key provided unfasten the four security screws.
Remove S/S dish.
Remove the S-Trap and unblock it.
Reattach the S-Trap.
Reattach the S/S dish and re-fasten the security screws.
What to do if the water bottle pod becomes blocked?
Use the security key provided.
Unfasten the security screws.
Remove the S/S mesh.
Unblock the pod.
What to do if the tap leaks?
Remove the S/S dish.
Turn off the isolation valve.
Disconnect the flexi hose.
Undo the hex connector at the base of
the tap.
Remove the spring.
Use an 8mm flat head screw driver to
remove the spindle.
Wash spindle or replace broken o-ring.
Don't forget to lube top o-ring.
Re-assemble tap.
(For better
purchase, do not remove
tap from S/S dish or from body of
aquaBUBBLER.)
Ensure the water-bottle
pod is full of water before
using the UA 2
aquaBUBBLER
(The water meter is an optional extra.)
>
>
>
IMPORTANT
We highly recommend regular cleaning, to ensure your UA 2 aquaBUBBLER is hygienic and attractive to drink from.