Simpool Pool-T Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump
ENGLISH
ADSP7000642
rev. 1.0
13/01/2014
51/72
The pump's overall operating time (dosing)
P.d.t
, from 0 to 999 hours, with the following format:
-
h.mm
up to 9 h and 59 m
-
hh.m
up to 99 h and 59 m (minutes expressed in tens)
-
hhh
up to 999 h
To reset each of the above-mentioned fields, just access from the numerical value the
rSt
reset entry with the F
key and from there select
YES
, confirming with
Enter
: the corresponding reset value will be visualized.
Fig. 12- Statistics Menu
To go back to the Programming Menu press
Enter
for 3 seconds.
3.3.3 Calibrating the Pump
The calibration of the pump allows to achieve more accurate dosing, as it allows to correct the dosing time in
relation to the actual flow rate of the pump. If the calibration is not carried out, dosing times would be calculated
based on the value of the pump rated flow rate value (read the value on the label).
The rated flow rate and the actual flow rate could differ for a number of reasons related to the use of the device
(wear of the peristaltic tube, etc.).
From the
CH.P
entry, you will be able to calibrate the pump for a fixed time of 60 seconds, thereby measuring the
amount of liquid dosed via a gr
aduated container used as a reference: from the start label “
StA
”, launch the count
by pressing
Enter
and the pump will start dosing at top speed. Finally, just set the amount in ml (from 0 to 300).