Simpool Pool-T Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump
ENGLISH
ADSP7000642
rev. 1.0
13/01/2014
44/72
3.0 PROGRAMMING
3.1 MAIN FEATURES
F
IG
.
5
-
U
SER
I
NTERFACE
The Increase/Decrease keys allow to change the numerical values and scroll through the lists of options for
all the available menu entries.
The Enter key allows to access and exit from the various entries of the submenus. Pressing the key for 3
seconds allows, from the Initial Menu, to access the Programming Menu and to go back to the Menu one
level up from the main entries on a Menu;
The Function key allows to browse through the Menu entries.
By pressing the key for 3 seconds from the initial page, you can access the User Menu;
T
WO
-
COLOURED
LED
The two-coloured LED displays the following conditions:
Steady green
: the pump is active;
Flashing green
:
the pump is dosing;
Steady red
: the pump is not active;
Flashing red
: there is an alarm;
Steady Orange
: if you are browsing the Programming Menu;
Flashing orange
:
Pump priming in progress;
The switch has three positions:
: the pump is active (ON)
O
: the pump is off (OFF)
: the pump is priming (MOM)
The MOM position is monostable, therefore after setting the switch to MOM, when it is released the
switch automatically goes back to OFF.
The pump doses for 60 seconds at the maximum speed; if the MOM key is pressed again before the
60 seconds elapse, the priming is interrupted.
OPERATION
The Pool-T model pump measures out chemical products for swimming pool water adjustment according to two
settings:
programmable cyclic mode. It runs the
Dosing Cycles
(composed by a Delay, a Dosing and a Block phase)
at the activation of the inhibitory signal of the recirculation pump. You can adjust the duration of the
phases;
relay mode, i.e. the pump starts dosing at the activation of the inhibitory signal of the recirculation pump,
and stops dosing when the signal is deactivated;
A dosing cycle is activated after the inhibitory signal of the recirculation pump goes off and is stabilized. A delay
time (adjustable from 0 to 999 sec.) will then follow: during this time, the pump stops working and waits to start