1.3 TECHNICAL FEATURES
1.3.1 ELECTRICAL FEATURES
For the power supply value we recommend reading the label on the pump!
1.3.2 PERFORMANCES
Maximum height of the suction tube: 1.5 m
Flow rate and back-pressure: see Tab. 1, read the label on the pump to identify the corresponding model.
Codes
Power supply
Motor
Type
Flow rate
(l/h)
Backpressure
(bar)
Peristaltic Tube
ADD91V4010000000
230 VAC
230 VAC
1.4
1
Santoprene
ADD9003010000000
230 VAC
230 VAC
3
1
Santoprene
Tab. 1
Temperature of the environment: 0 ÷ 45°C
Packaging and transport temperature: -10 ÷ 50 °C
Protection degree: IP65
2.0 INSTALLATION
2.1 GENERAL RULES
Pump installation must be carried out as follows:
In vertical position, with an inclination below +/-15°.
Away from sources of heat in dry locations, at a maximum temperature of 40°C and a minimum of 0°C.
In a ventilated location that can be easily accessed for periodical maintenance.
Above the level of the liquid that needs to be dosed, at a maximum height of 1.5 metres.
Do not install the pump above the tank when using liquids that emit fumes, unless it is sealed shut.
2.2 INSTALLATION KIT
The pump is supplied with all items required for correct installation. The full kit supplied is reported in Figure 1
(Viton 1/2" pool peristaltic pump accessories -
code ADSP6000037
) and includes:
g) PVC ø 4x6 4ml suction and delivery tubes
(code ADSP6000551);
h) Bracket;
i) Wall plugs and screws;
j) G 1/ 2" Duckbill injection valve
(code ADSP6000049);
k) Foot strainer 4x6
(code ADSP6000001);
The pump can be connected to a level probe that is not supplied as standard:
l) Level probe with BNC
(code ADSLG4);
Other optional accessories:
Collar DN50 - G 1/ 2"
(code ADSP6000111);
Collar DN63 - G 1/ 2"
(code ADSP6000113);