
HC151+CST / HC151+PImA / HC200+CST
ENGLISH
7
2.3
HYDRAULIC FEATURES
Hydraulic characteristics of the 230V version
SOLENOID
TYPE
FLOW RATE PRESSURE
STROKES
INJECTION
VALUE
ABSORBED
POWER
l/h
bar
spm
ml/stroke
Watt
60
A
1
7
100
0,17
13
5
1
0,83
13
B
3
7
150
0,33
16
9
1
1
16
C
5,5
6
180
0,51
22
10
1
0,93
22
70
A
1,8
20
75
0,40
18
4
1
0,89
18
B
4
12
120
0,56
25
7
1
0,97
25
C
5,8
9
180
0,54
27
14
1
1,30
27
80
(only HC151)
A
4
20
150
0,44
24
10
1
1,11
24
B
6,5
12
200
0,54
27
13
1
1,08
27
C
13,5
5
300
0,75
35
20
1
1,11
35
The above data refer to tests carried out with water at room temperature. Values can fluctuate by 10%.
With chemical products with a different viscosity than that of water, the flow rate data may undergo even
sensitive variations.
Hydraulic characteristics of the 110V version
SOLENOID
TYPE
FLOW RATE PRESSURE
STROKES
INJECTION
VALUE
ABSORBED
POWER
l/h
bar
spm
ml/stroke
Watt
60
A
1,5
7
100
0,25
18
5
1
0,83
18
B
4,5
7
150
0,5
23
7
1
0,78
23
C
6
6
180
0,56
28
8,8
1
0,81
28
70
A
1
20
75
0,22
21
4,5
1
1
21
B
4
12
120
0,56
31
7
1
0,97
31
C
6,8
9
180
0,63
41
10,8
1
1
41
80
(only HC151)
A
3
17
150
0,33
27
10
1
1,11
27
B
7,5
12
200
0,63
36
13
1
1,08
36
C
11
5
230
0,80
44
16
1
1,16
44
The above data refer to tests carried out with water at room temperature. Values can fluctuate by 10%.
With chemical products with a different viscosity than that of water, the flow rate data may undergo even
sensitive variations.
Содержание HC151+CST
Страница 2: ...HC151 CST HC151 PImA HC200 CST ENGLISH 2...
Страница 19: ...HC151 CST HC151 PImA HC200 CST ENGLISH 19...
Страница 20: ...HC151 CST HC151 PImA HC200 CST EXPLODED VIEWS HC151...
Страница 22: ...HC151 CST HC151 PImA HC200 CST ADSP9500072 20 04 2021 Rev 2 0 22 28 HC200...
Страница 24: ...HC151 CST HC151 PImA HC200 CST ADSP9500072 20 04 2021 Rev 2 0 24 28 PUMP HEAD...