HC150 / HC101
INTRODUCTION
Analog solenoid driven dosing pump
ENGLISH
ADSP9500090
Rev.2.5 09.09.2015
24
Accordingly, we consider it necessary to follow the contents of this manual carefully,
especially regarding maintenance, in order to obtain an elevated level of reliability and
long-lasting operation.
The manufacturer declines all responsibility for any intervention on the equipment
carried out by unqualified personnel.
1.5 Technical features
General
Power supply: 230VAC ± 15% - 50/60Hz
Average absorption at the maximum frequency of operation: 16 W.
Maximum frequency of operation HC150: 120 BPM (mod. 1 and 2) 150 BPM (mod. 3).
Maximum frequency of operation HC101: 120 BPM (mod. 1), 150 BPM (mod. 2 e 3), 180 BPM
(mod. 4), 75 BPM (mod. 5).
Level input
Connection through a black BNC connector.
Voltage-free contact (NPN transistor).
Pulse input - only model HC150 / HC101 PI
Connection through a red BNC connector.
Piloting is performed with a voltage-free control (reed) or with an NPN transistor.
Maximum frequency: 100 Hz.
Minimum on and off time of the pulse: 5 ms.
Current input - only model HC150 / HC101 mA
Connection through a red BNC connector.
Proportionality interval: 4…20 mA.
Maximum input current: 25 mA.
Resistive load: 120 ohm.
No galvanic separation
.