Aqua F-123 Скачать руководство пользователя страница 2

 

 

 

 

 

MAIN

 

DRAIN

IMPORTANT

This

 

instruction

 

manual

 

includes

 

essential

 

information

 

on

 

the

 

safety 

 

to

 

be

 

implemented

 

for installation

 

and

 

start

-

as

 

the

 

user must

up

Therefore

the

 

installer

 

as

 

well 

read

 

the

 

instructions

 

before

 

starting

 

installation

 

and

 

start

-

up

Keep

 

this

 

manual

 

for future

 

reference

.

1

. -

MAIN

 

DRAIN

:

 

Main

 

drains

 

are

 

used

 

to

 

take

 

out

 

water

 

from

 

the

 

deepest

 

part

 

of

 

the

 

pool

 

 

2

. -

INSTALLATION

:

 

According

 

to

 

the

 

normative

main

 

drains

 

have

 

to

 

be

 

installed

 

as

 

following

:

 

-

Main

 

drains

 

have

 

to

 

be

 

installed

 

in

 

the

 

deepest

 

part

 

of

 

the

 

pool

.

 

-

The

 

minimum

 

distance

 

between

 

two

 

main

 

drains

 

is

 

2

 

meters

.

 

-

The

 

minimum

 

distance

 

between

 

the

 

main

 

drain

 

and

 

the

 

wall

 

of

 

the

 

pool

 

is

 

300

 

mm

.

-

The

 

maximum

 

water

 

velocity

 

through

 

the

 

grille

 

is

 

0

.

5

 

m

/

sec

.

 

-

The

 

maximum

 

water velocity

 

in

 

the

 

suction

 

pipe

 

until

 

the

 

filtration

 

pump

 

is

 

1

.

5

 

m

/

sec

.

The

 

flow

 

rate

 

required for

 

the

 

installation will

 

determine

 

the

 

number

 

of

 

main

 

drains needed

.

The

 

maximum

 

flow

 

rate

 

allowed

 

is

 

13

 

m

3

/

h

.

Fig

1

Recommends

 

to

 

install

 

a

 

hydrostatic

 

valve

(

not

 

included

 (

BSP thread

 

1

 

½”

),

 

in

 

order to relieve

 

the

 

pressure

 

that  

 

potential ground

-

water might

 

exert

 

 

on

 

the

 

pool

 

structure

especially

 

when

 

it

 

is

 

empty

 

or

 

it

 

is

 

Vinyl

 

pool

.

 

4

.-

WARNINGS

:

 

SUCTION

 

ENTRAPMENT

 

HAZARD

 

Suction

 

in

 

suction

 

outlets

 

and

/

or

 

suction

 

outlet

 

covers

 

which

 

are

 

damaged

broken

cracked

missing

or

 

unsecured

 

can

 

cause

 

severe

 

injury

 

or

 

death

 

due

 

to

 

the

 

following

 

entrapment

 

hazards

:

4

.

1

. -

Hair

 

Entrapment

  -

 

Hair

 

becomes

 

knotted

 

or

 

snagged

 

in

 

an

 

outlet

 

cover

.

4

.

2

. -

Limb

 

Entrapment

  -

 

A  limb

 

sucked

 

or

 

inserted

 

into

 

an

 

op ening

 

of

 

a

 

circulation

 

swelling

Concrete

 

pools

F-123

3

. -

MODELS

 

 

 

 

Imperial 

 

connections

 

Suction

 

Circuit

 

Hydrostatic 

 

valve

 

connection

 *

 

 

1

 

½

 

 

for

 

the

 

recirculation process

It

 

is

 

also

 

used

 

to

 

drain

 

the

 

pool

.(

Fig

 

1

)

 

4

.

3

. -

Body

 

Suction

 

Entrapment

 

-

 

Suction

 

applied

 

to

 

a

 

large

 

portion

 

of

 

the

 

body

 

or

 

limbs

 

  resulting

 

in

 

an entrapment

.

4

.

4

. -

Mechanical

 

Entrapment

  -

Potential

 

for

 

jewelry

,

swimsuit

,

hair

 

decorations

,

finger

,

toe

 

or

 

knuckle

 

to be

 

caught

 

in

 

an

 

opening

 

of

 

an

 

outlet

 

or

 

cover

.

outlet with a broken or missing cover in the pool resulting in a mechanical bind or 

 

5

.-

SPARE PARTS

 

LIST

:

1

2

3

POS

.

CODE

PRODUCT DESCRIPTION

1

03017125

Screws M5x10

2

01050195

Lid

3

01050198

Body

measures

G2”

on

 

the lower

 

outlet

 

of

 

the main

 

drain

Отзывы: