Electrical connection

■  

 

The units are

 

operated 
with 220 V 

50 Hz

alternating current

.

 

 

   

The electrical connection 
is made using a built

-

in mains 

cable with earthed safety plug

■  

 

Extensions to the connection 
cable may only be carried out 
by authorised electricians

subject to the length 
of the cable

connected load 

of the unit and taking into 
consideration how the unit 
is used at its location

Set

-

up

For the best economic and safe use 
of the units

the following notes 

must be followed in full

 

■  

 

The units must be set 
up in an upright and level 
position

so as to ensure

 

unobstructed flow 
of the condensate

■   

To

 

ensure

 

optimum

 

air

 

circulation

the

 

units

 

should

 

be set up in the centre

 

of the room

where

 

possible

■  

 

It must be ensured

 

that

 

the

 

air

 

can be sucked in on the front

 

of the unit and blown out 
of the rear

 

of

 

the

 

unit

 

without

 

obstruction

■  

 

Observe a minimum clearance 
of 50cm from

 

walls

 

at

 

all

 

times

■   

Units must never be set 
up in the immediate vicinity 
of heaters or other sources

 

of heat

■  

 

Air circulation

 

is

 

improved

 

if the unit is set up approx

1 m 

above the ground

 

■  

 

The room

 

being

 

dried

 

or dehumidified must be closed 
to the neighbouring atmosphere

■  

 

Avoid

 

having

 

opened

 

windows

 

and doors etc

., 

and avoid 

frequent

 

entry

 

to

 

or

 

exit

 

from

 

the room

 

as

 

much

 

as

 

possible

■   

If the units are

 

to

 

be

 

used

 

in dusty environments

 

or stables

appropriate

 

care

 

and maintenance measures

 

should be taken according

 

to the relevant

 

conditions

■  

 

The output of the unit is entirely

 

dependent on the conditions 
inside the room

room

 

temperature

relative

 

humidity

 

and observance of the set

-

up 

instructions

NOTE

The

 

electrical

 

connection

 

to the

 

units

 

must

 

be

 

made

 

at feed 

points

 

with

 

residual

 

current

 

devices

 

in

 

accordance

 

with

 

VDE

 

0100

Section

 

704

.

When

 

installing

 

the units

 

in 

extremely

 

damp

 

environments

 

such

 

as

 

laundry

 

rooms

showers

 

etc

., 

the customer

 

must

 

ensure

 

that

 

the

 

unit

 

is

 

secured

 

with

 

a

 

residual

 

current

 

device

 

in 

accordance

 

with

 

the regulations

.

Wall

 

clearance

min

0

.

5 m

Maintain adequate clearance from 
heaters or other sources of heat

.

Keep

 

window

s

 

and

 

doors

 

closed

!

ATTENTION

All cable extensions must 
only be used in a rolled out 
or unrolled state

.

!

Air dehumidifIers

9

Содержание DH-15

Страница 1: ... INSTALLATION AND INSTRUCTION MANUAL www aqua it DHseries Technology Operation Replacement parts Airdehumidifers AQUA Read these operating instructions carefully before commissioning using this device DH 15 DH 6 DH 4 DH 2 ...

Страница 2: ......

Страница 3: ...liabilityaccepted forerrors ormisprints Airdehumidification 4 Safetynotes 6 Intended use 7 Customerservice andwarranty 7 Environmental protection and recycling 7 Unitdescription 8 Set up 9 Commissioning 10 Decommissioning 12 Transportation 12 Care and maintenance 13 Troubleshooting 14 Electrical connection diagram 15 Maintenance protocol 16 Technical data 17 3 Air dehumidifIers ...

Страница 4: ...released from parts of a building ormaterials is absorbed bythe surrounding air As a result the moisture content increases which ultimatelygives rise to corrosion mould rot peeling ofpaintand otherunwanted damage Bywayofexample the diagram shows the corrosion rate of metal in different levels of humidity Air dehumidification With regard to energy consumption airdehumidification has one distinctadv...

Страница 5: ... iteasierfor the temperature to fall below it Building materials and structures are capable of absorbing considerablevolumes ofwater such as brick90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m The drying ofmoistmaterials such as masonryis effected as follows The moisture moves from the inside ofthe material to its surface Evaporation occurs on the surface Transfer ofwatervapourto ...

Страница 6: ...d to a greater extent by the speed at which the material or building section loses its moisture Safety notes The unitswere subjected to exten sive material functional and qual ityinspections priorto delivery However dangers can emanate from the units if they are used improperly or not as intended by untrained personnel The following notes mustbe observed in full The units maynotbe installed oroper...

Страница 7: ...terials are environmentally friendly and can be recycled Byrecycling packaging materials you make avaluable contribution to the reduction of waste and conservation ofrawmaterials Therefore only dispose of packaging material at appropriate collection points Disposal of the old unit The manufacturing process for the units is subjectto continuous qualitycontrol Onlyhigh grade materials are processed ...

Страница 8: ...he cooled and dehumidified air is re heated by the condenser heatexchanger and blown back into the room through the outlet grille The processed dry heated airthen re mixes with the room air Continuous circulation of the room airthrough the unit gradually reduces the relative humidity RH in the room to the desired humiditylevel Depending on the room temperature and the humidity only30 40 electrical...

Страница 9: ...s ofheat Aircirculation is improved ifthe unitis setup approx 1 m above the ground The room being dried ordehumidified mustbe closed to the neighbouring atmosphere Avoid having opened windows and doors etc and avoid frequent entry to or exit from the room as much as possible Ifthe units are to be used in dustyenvironments orstables appropriate care and maintenance measures should be taken accordin...

Страница 10: ... orfilter mustbe cleaned orreplaced immediately NOTE In room temperatures below 10 C and relative humidity below40 economical use ofthe unitcan no longer be guaranteed NOTE The units are only functionalwhen operatedwith a correctlyinserted condensate container Air dehumidifIers Turn ON orOFF Enterparametersetting status Check or set the parameter Invalid Set timer Targethumidityvalue Measuredvalue...

Страница 11: ...C2 C3 C4 C5 C6 C7 Heating function Condensation coil temperature Humidity sensor detects deviation Press after opening delay detection time Enter the defrost point temperature Exit defrost point temperature Maximum defrost time Parameter Description Default values Code Meaning Para meter No 0 1 1 20 99 5 5 0 20 90min 40 10 10 1 0 15 8 2 12min 8 Press the 3 seconds to enterthe parameterquerysetmenu...

Страница 12: ...densate into a lower lying drain To operate the units the condensate containermust always be inserted correctly and the sealing flap mustalways be locked NOTE Ensure thatthe drainage hose is placed atan angle to the drain to allow the condensate to drain from the condensate container withouthindrance The following procedure must be followedwhen connecting awaterhose 1 Open the frontsealing flap an...

Страница 13: ...re and maintenance All moving parts have a low maintenance permanentcoat oflubricant The refrigerant system is designed as a hermeticallysealed system and mayonlybe repaired bya specialist NOTE Regularcare and maintenance is fundamental to a long service life and fault free operation ofthe unit ATTENTION Before undertaking any workon the units the mains plug mustbe removed from the mains socket Ke...

Страница 14: ...control lamp should illuminate Check mains connection 220V 1 50 Hz Checkmains plug and cable for damage Checkthe customer provided mains protection Minimum protection 10A Checkthe level and correct positioning ofthe condensate container The front sealing flap must be fullyclosed and locked Checkthe function ofthe micro switch Checkthe setting ofthe humidityswitch accessories The pre set value must...

Страница 15: ...5 FM CM Y G WIRE CONTROLLER HIGH PRESSURE LOW PRESSURE TRANSFORMER U V W AMBIENT TEMPERATURE COIL TEMPERATURE OBLIGATE OBLIGATE YW BK RD HUMIDITY TEMP FM L K1 N A B C phase relay 380V 3 Phase 50Hz OUT 1 COMP CN19 LED 4 WAY FM H AC N CN1 CN2 SW1 220V AC 12V AC OUT3 OUT4 OUT5 FM CM Y G WIRE CONTROLLER HIGH PRESSURE LOW PRESSURE TRANSFORMER N L R S C AMBIENT TEMPERATURE COIL TEMPERATURE OBLIGATE OBLI...

Страница 16: ... Date Signature 19 Date Signature 20 Date Signature Comments Unit type Unit number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Unitcleaned outside Unitcleaned inside Fan blade cleaned Fan housing cleaned Condensercleaned Vaporiser cleaned Fan function checked Air inlet grid with flter cleaned Unitchecked fordamage Safetydevices checked All fastening screws checked Electrical safetycheck Tes...

Страница 17: ...kg DH 15 3 32 40 100 15 2 15 0 4500 Φ20 Scroll R22 2400 380V 3 50 8 1 2 3 6 2 40 Hotgas 53 770 770 995 1090 165 1 Noise level measurement DIN 45635 13 KL 3 2 Dimensions in withouttransportation bracket We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process Technical data Air dehumidifIers 17 DH 6 3 32 40 100 6 2 6 0 2800 Φ20 Rot...