Aqua 72027 Скачать руководство пользователя страница 3

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

Check the air release hose are fixed well on the body of lateral holder, and another end of the air 

release hose must be out of the sand. DO NOT embedding the air release hose in the sand.   

4

 

 

To  eliminate  stress  on  the  laterals,  fill  the  filter  vessel  with  enough  water  to  provide  a 

cushioning effect when the filter sand is poured in.   

5

 

 

Using  the  clear  clamshell cover  to protect the filter top mount  and  make  sure  the  central  stem 

pipe had been fully covered.   

6

 

 

Carefully pour the sand into the filter  vessel  and  make  sure  to prevent sand  from  entering the 

stem pipe. And meantime do not damage the filter top mount or it will cause the leakage. And 

please pour the quantity of sand according to the filter tank label.   

7

 

 

Cleaning the filter top mount put the O-ring on the top mount valve and then installs the valve 

on the filter vessel. Make sure that the stem pipe had fixed well with the top mount valve, and 

tight the flange clamp to fix the valve. NOTE: the flange clamp should be well fixed, or it will 

cause the people injures.   

8

 

 

Using  screws from  the pump  hardware pack  to fix  the pump on  the base, please reference  the 

pump installation to operate the pump.   

9

 

 

Adjust the valve position, using the white pressure hose to connect the pump output and input of 

the top valve (

!

TO PUMP

"

 are curve on the valve of input end).   

10. The other two connection ends of the valve, one is connection to swimming pool (it curved 

!

TO 

POOL

"

 on it) and another one is connect with drain outlet hose.   

 

INSTALLATION NOTES: 

1

 

 

Make sure the filter is worked under the work pressure, and using a pressure control valve when 

the system using a booster pump.   

2

 

 

If the pump position is higher than the water level, it requires installing the back water control 

valve. 

3

 

 

If  the  pump  position  is  lower  than  the  water  level,  it  requires  installing  an  isolation  valve.  It 

could stop the water return back when people do the general inspection.   

4

 

 

Reducing the connect adaptors and hose connecting bending as less as possible. Decreasing the 

water flow scrub, it could reach the maximum effective. 

5

 

 

Ensure  solvents are not  excessively applied  to  fittings as  this  could run  into  O-ring and create 

sealing problems. 

6

 

 

Do not over tighten fittings or adapters 

 

HOW TO USE 

1

 

 

Inspect all the connections have been made correct and are secure.   

Raised point 

Содержание 72027

Страница 1: ...Sand filter system instruction ...

Страница 2: ...act the supplier or its nearest authorized service agent Sand Filtration working principle Incoming water from the piping system is automatically directed by the Multiport Valve to the top of the filter bed As the water is pumped through the filter sand dirt and debris are trapped by the filter bed and filtered out The filtered water is returned from the bottom of the filter tank through the Multi...

Страница 3: ... the pump hardware pack to fix the pump on the base please reference the pump installation to operate the pump 9 Adjust the valve position using the white pressure hose to connect the pump output and input of the top valve TO PUMP are curve on the valve of input end 10 The other two connection ends of the valve one is connection to swimming pool it curved TO POOL on it and another one is connect w...

Страница 4: ...ng is 8 10 PSI 0 55 0 69 BAR higher than the initial clean pressure you noted it is the time to backwash clean the filter 2 IMPORTANT To prevent unnecessary strain on piping system and valving always shut off pump before switching filter control valve position 3 To prevent damage to the pump and filter and for proper operation of the system clean pump strainer and skimmer baskets regularly FILTER ...

Страница 5: ...1 8 0 16 110 50 72059 44 10 50 3 5 2 5 0 23 220 100 72060 53 12 50 3 5 3 6 0 34 350 160 72255 30 6 8 50 3 5 1 8 0 16 110 50 72258 44 10 50 3 5 1 8 0 16 110 50 72259 44 10 50 3 5 2 5 0 23 220 100 72260 53 12 50 3 5 3 6 0 34 350 160 72062 44 10 50 3 5 1 8 0 16 110 50 72063 44 10 50 3 5 2 5 0 23 220 100 72064 53 12 50 3 5 3 6 0 34 350 160 72262 44 10 50 3 5 1 8 0 16 110 50 72263 44 10 50 3 5 2 5 0 23...

Страница 6: ...7306173 Air release assembly for 73060 1 6a 647304008 Filter tank for 73040 1 6b 647305008 Filter tank for 73050 1 6c 647306008 Filter tank for 73060 1 7 647304072 Flange clamp 1 8 65431012080 O ring 1 9 647304071 6 way valve 1 10 65431021080 O ring 3 11 647303014 Hose adaptor 3 12 65021005000 Hose clamp 2 13 65749002011 1 1 2 38mm hose for 72041 72241 1 14 647201802001 Adaptor for 72027 72028 720...

Страница 7: ...HP Pump 115V 60HZ for 72242 1 20b 72743 1 0HP Pump 115V 60HZ for 72243 1 21a 647201273 Screw M6X25 and Nut M6 for 72041 72241 4 21b 65862026000 Screw M8X35 and Nut M8 for 72027 72028 72029 72228 72229 72230 4 Screw M8X35 and Nut M8 for 72042 72043 72242 72243 2 Parts Listing 72055 72255 72058 72059 72060 72258 72259 72260 72062 72063 72064 72262 72263 72264 Ref No Part No Description QTY 1a 647304...

Страница 8: ...or 72029 72230 1 15b 647206371 PVC hose for 72042 72242 1 647204371 PVC hose for 72043 72243 1 16a 72515 0 35HP Pump 230V 50HZ f or 72041 1 16b 72715 0 35HP Pump 115V 60HZ f or 72241 1 17a 72527 0 5HP Pu mp 230V 50HZ f or 72027 1 17b 72528 0 75HP Pump 230V 50HZ f or 72028 1 17c 72529 1 0HP Pu mp 230V 50HZ f or 72029 1 18a 72728 0 75HP S PL Pump 115V 60HZ f or 72228 1 18b 72729 1 0HP SP L Pump 115V...

Отзывы: