NOTE:
If you touch the Lamp use denatured alcohol and a soft cloth to clean the Lamp. If you
do not clean the Lamp the fingerprints will become etched into the glass which will diminish
UV output and may cause premature lamp failure.
NOTE:
Lamps and Quartz Sleeves should be handled with care. Lamps and Quartz Sleeves
are not warranted against breakage or damage.
WARNING:
Do not install the Lamp at an angle (even a slight angle); this may cause a U
shaped crack at the end of the Quartz Sleeve, or possible breakage of the Lamp. If this
should happen, do not proceed with the installation. Purchase a new Quartz Sleeve or Lamp
from your dealer and refer to the proper installation instructions.
NOTE:
Do not force the Lamp into the Quartz Sleeve.
1.
Unscrew the Davis Connector located behind the Transformer
Cap, this allows your Transformer Cap to spin freely.
2. Plug the Lamp flush into the Lamp End Connector before inserting the Lamp into the unit.
If the Lamp is not plugged in all the way it may cause damage to the unit and is not covered
under warranty
.
5.
Tighten the Davis Connector back on to the
Transformer Cap.
3. Insert the Lamp straight into the Quartz Sleeve. Be careful, inserting the Lamp at an angle, even
a slight angle, can cause a "U" shaped crack in the Quartz Sleeve.
Quartz Sleeves are not warranted against breakage or damage.
4. Twist the Transformer Cap onto the
Quartz Cap. Do not over tighten.
This is a connection only and is not
in contact with water.
Screw on
Transformer Cap
Screw on
Davis Connector
INSTALLING THE LAMP
For 8, 15, 25, 40, 57 and 114 Watt Units
6.
FINAL LEAK CHECK
:
Do not plug the Sterilizer into power yet, turn on the pump, let water run for
5 minutes and check for leaks. (See page 16 for trouble shooting leaks).
7. Once a leak test is completed, and there are no leaks, plug the Transformer into a GFCI outlet.
Davis Connector
Lamp End Connector
Transformer Cap
Quartz Cap