NOTE:

 If you touch the Lamp use denatured alcohol and a soft cloth to clean the Lamp. If you 

do not clean the Lamp the fingerprints will become etched into the glass which will diminish 

UV output and may cause premature lamp failure.

NOTE:

 Lamps and Quartz Sleeves should be handled with care. Lamps and Quartz Sleeves 

are not warranted against breakage and damage.

WARNING:

 Do not install the Lamp at an angle (even a slight angle); this may cause a U 

shaped crack at the end of the Quartz Sleeve, or possible breakage of the Lamp. If this 

should happen, do not proceed with the installation. Purchase a new Quartz Sleeve or Lamp 

from your dealer and refer to the proper installation instructions.

NOTE:

 Do not force the Lamp into the Quartz Sleeve.

NOTE: 

To achieve the optimum kill rates UV must run continuously. Constant "On and Off" 

shorten the life of the lamp and the transformer.

INSTALLING THE LAMP

1.

 

Unscrew the Davis Connector located behind the Transformer 

    Cap, this allows your Transformer Cap to spin freely.

2. Plug the Lamp flush into the Lamp End Connector. 

    If the Lamp is not plugged in all the way it may cause 

    damage to the unit and is not covered under warranty

.

6.

 FINAL LEAK CHECK

Do not plug the Sterilizer into power yet, turn on the pump, let water run for   

   5 minutes and check for leaks.

5.

 

Tighten the Davis Connector located behind the  

    Transformer Cap.

3. Insert the Lamp straight into the Quartz Sleeve. Be careful, inserting the Lamp at an angle, even  

    a slight angle, can cause a "U" shaped crack in the Quartz Sleeve.

4. Screw on the Transformer Cap. Do not over 

    tighten. This is a connection only and is not in 

    contact with water.

7. Once a leak test is completed, and there are no leaks, plug the Transformer into a GFCI outlet.

Screw on

 Transformer Cap

Screw on

 Davis Connector

Davis Connector

Lamp End Connector

Transformer Cap

Содержание Advantage 2000

Страница 1: ...90 TOLL FREE 800 454 2725 TEL 951 296 3480 FAX 951 296 3490 www aquauv com ULTRAVIOLET STERILIZER Find us on Facebook www facebook com AquaUltraviolet Follow us on Twitter www twitter com aquaultravio...

Страница 2: ......

Страница 3: ...ion How Ultraviolet Works Sizing Chart Frequently Asked Questions Pond Aquarium Layouts Hanger Installation Instructions Barb X Barb Installation Instructions Trouble Shooting Leaks Installing The Lam...

Страница 4: ...Should you encounter any problems with your product please call our toll free HELP line for assistance 1 800 454 2725 PLEASE DO NOT return your product to the store Your dealer or distributor cannot...

Страница 5: ...t and the user agrees that no other remedy is available Before installing the user shall determine the suitability of the product for their intended use and the user shall assume all risk liability wh...

Страница 6: ...ranty or repair Please have your serial number date of purchase and product type available when calling for an RMA number All warranty returns or repair returns must come freight prepaid with an RMA n...

Страница 7: ...ompletely sterilize your pond aquarium as the pond aquarium itself is not a sterile environment As a control this unit will effectively lower your water bacterial count allowing your fish to stay heal...

Страница 8: ...een a sterilizer and a clarifier As a sterilizer your Aqua UV system will keep your pond or aquarium water crystal clear plus you will have the added benefit of bacterial control which will help keep...

Страница 9: ...l Pump And Filter Out From Pond Return To Pond Advantage Hanger Unit External Pump And Filter Out From Aquarium Return To Aquarium Advantage Unit External Pump And Filter Out From Aquarium Return To A...

Страница 10: ...l the UV Lamp Transformer and plug in the electrical cord a leak test must be conducted LEAK TEST Do not install Lamp or electrical components yet After all the hose connections have been made turn th...

Страница 11: ...amps are not included purchase separately along with your hose 2 Connect a hose to opposite barb and secure with hose clamps Hose should return water to the opposite end of your aquarium or pond 3 Bef...

Страница 12: ...ap and finger tighten Do not use a pipe wrench pliers or any other tool Hand tighten only Leaks from Center of Quartz Sleeve 2 The Quartz Sleeve is broken and needs to be replaced Neither the broken Q...

Страница 13: ...m kill rates UV must run continuously Constant On and Off shorten the life of the lamp and the transformer INSTALLING THE LAMP 1 Unscrew the Davis Connector located behind the Transformer Cap this all...

Страница 14: ...de the Lamp out at an angle even a slight angle this may cause a U shaped crack at the end of the Quartz Sleeve or possible breakage of the Lamp 3 Unscrew the Transformer Cap 2 Unscrew the Davis Conne...

Страница 15: ...screw Transformer Cap Unscrew Davis Connector NOTE The Lamps and Quartz Sleeves should be handled with care Lamps and Quartz Sleeves are not warranted against breakage and damage Quartz Sleeve Purple...

Страница 16: ...f an extension cord is necessary a cord with a proper rating should be used a cord rated for fewer amperes or watts than the unit rating may overheat Care should be taken to arrange the cord so that i...

Страница 17: ...artz Cap Quartz Sleeve Quartz Cap INCORRECT Lamp at an Angle will Create a U Shaped Crack Lamp Quartz Cap INCORRECT Lamp not Plugged Flush with Lamp End Connector CORRECT Lamp Lamp End Connector Lamp...

Страница 18: ...al charge Aqua Ultraviolet shall not be responsible for damage or loss done by the shipper Nor shall Aqua Ultraviolet be respon sible for merchandise that arrives damaged due to improper packaging All...

Страница 19: ......

Страница 20: ...42371 Avenida Alvarado Temecula CA 92590 TOLL FREE 800 454 2725 TEL 951 296 3480 FAX 951 296 3490 www aquauv com R 07222011 A11042...

Отзывы: