The sensor head is screwed into inspection openings of existing
water pipes or other suitable locations via a ¼ inch thread. If no
inspection opening is available it is possible to use the edge
valve below a sink or beside a toilet. For this option the
installation is described below.
To make it short and easy – the video on
explains the installation of the Aqua-Scope Sensor Head step by
step:
1.
In case there are two edge valves under the sink, please
identify the cold-water supply. Just open hot water and
check which valve warms up.
2.
Close the faucet and close the edge valve by turning
clockwise.
3.
Remove the metal hose from the edge valve using the 19
mm wrench supplied. You may want to have a towel on
hand to catch the water leaking from the end of the hose.
4.
Mount the T-shaped connector on top of the edge valve
and fasten it using the 19 mm wrench.
5.
Connect the metal hose to the upper end of the connector
and fasten it using the 19 mm wrench.
6.
Screw the Aqua-Scope pressure sensor head into the side
opening of the connector and fasten it by hand. There is no need to make it super-tide.
7. Re-Open the edge valve by turning the knob anti-clockwise.
8. Please check all three connections for some seconds that there are no leaks.
9. Attach the Aqua-Scope to a suitable location using double-side tape and plug the sensor head into
the water-proof screwable terminal of the main device. Attach the wired flood sensor to the small
round terminal if desired.
10. Power the device using the USB C Power Plug. Please use the power supply provided within the
scope of delivery. This power supply has very low distortion factor required for precise
measurements of pressure.
Reset to Factory Default State
The factory default state is indicated by the LEDs blinking green/red. Please push the button after the
initial buzzer beep (but not earlier!) and keep it pushed for 5 seconds. After 5 seconds you hear a low-
frequency sound. Now release the button! This reset sequence will delete all settings including network
access credentials.
WIFI Network Setup
Users and Installation Manual: Water Pressure Sensor (PREWIE02)
Copyright © 2022 Aqua-Scope Technologies, Sakala tn 7-2, 10141 Tallinn, Estonia, www.aqua-scope.com