background image

-

2

 - 

 

 

 

Description 

The self-priming pool pump is designed for high efficiency and easy installation and maintenance. It is constructed 
for years of trouble-free service. This swimming pool pump is designed for use with permanently installed swimming 
pools only. 

 
Unpacking 

After unpacking the unit, carefully inspect for any damage that may have occurred during transit. Check for loose, 
missing or damaged parts 
 

INSTALLATION 
Only qualified, licensed personnel should install pump and wiring. 

The pump mount must be located away from corrosive or flammable chemicals. 

 
IMPORTANT SAFETY INSTRUCTIONS 
Always follow basic safety precautions with this equipment, including: 

 
To reduce the risk of injury, do not allow children to use product unless supervised at all times. 
 
This pump is for use with permanently installed pools. Do not use with portable pools. A permanently installed pool is 
constructed in or on the ground or in a building and is not intended to be disassembled or moved. 
     
Provide sufficient ventilation to maintain air temperature below the maximum ambient temperature rating shown on 
the motor nameplate. Any enclosure or pump house must allow adequate ventilation to assure the ambient 
temperature remains below the motor rating when the pump is operating. 
 
Locate pump on a non-combustible surface as close to the pool/spa as possible. The surface should be hard, level, 
dry, and well ventilated. The surrounding area should provide protection from the elements and allow sufficient space 
for maintenance and service. Ensure the drainage will flow away from the pump. To reduce vibration and pipe stress, 
use anchor bolts to secure the pump base to the surface. 
 
Design the piping system to allow the pump suction inlet height to be as close to the water level as possible. Mount 
the pump below water level for easy priming. If the pump must be located above the filled water level, keep the 
vertical distance to a minimum. Use short, direct piping to the suction to minimize friction loss.     
 

Fire and burn hazard. 

Motors run at high temperatures. Do not allow leaves, debris, or foreign matter to collect 

around the pump motor. Allow the motor to cool before handling. 
 
Use rigid or flexible PVC pipe. Ensure pipe ends are clean and free of any flash caused by cutting. Use proper glue 
for the type of pipe selected.   

 
NOTE: 

Use a supplier recommended primer to ensure glued joints are secure. Many local codes require primer with 

a purple tracer to verify primer use. 
 
Consider climatic conditions when applying adhesives. Atmospheric conditions with high humidity will make the 
adhesive action of certain glues less effective. Follow the manufacturer's instructions. 

Содержание SINGLE SPEED

Страница 1: ...can create hazards which could result in property damage serious injury or death Improper installation will void the warranty The NOTICE label indicates special instructions that are important but not related to hazards Notice to Installer This manual contains important information about the installation operation and safe use of this product Once installation is complete this manual must be given...

Страница 2: ...tor rating when the pump is operating Locate pump on a non combustible surface as close to the pool spa as possible The surface should be hard level dry and well ventilated The surrounding area should provide protection from the elements and allow sufficient space for maintenance and service Ensure the drainage will flow away from the pump To reduce vibration and pipe stress use anchor bolts to se...

Страница 3: ...ads with one to two layers of Teflon tape Cover entire threaded portion Do not over tighten If leaks occur remove pipe clean off old tape rewrap with one to two additional layers of tape and remake the connection Fittings Fittings restrict flow for best efficiency use the fewest number of possible fittings Avoid fittings which could cause an air trap Pool fittings must conform to International Ass...

Страница 4: ...or seriously damage motor and voids warranty Voltage Voltage at motor must be within 10 of the motor nameplate rated voltage or motor may overheat causing overload tripping and reduced component life If voltage does not fall within the specified range during operation consult the power company Grounding Bonding Install ground bond and wire motor according to local or National Electrical Code requi...

Страница 5: ... higher than pump pump will prime automatically during suction and discharge valves are opened If the pump is located above the normal pool water level remove ring and cover assembly and fill basket and pump with water Clean and inspect o ring then reinstall on trap Replace ring and cover assembly then rotate clockwise to tighten cover NOTICE Tighten ring and cover assembly by hand do not use tool...

Страница 6: ...d electrically test the pump motor FAILURE TO PUMP REDUCED CAPACITY OR DISCHARGE PRESSURE Suction leaks lost prime 1 Pump must be primed Make sure that pump body and basket body are full of water See priming instructions 2 Make sure there are no leaks in suction piping 3 Make sure suction inlet is well below the water level to prevent pump from sucking air 4 Pump is designed to prime at a vertical...

Страница 7: ...tion and discharge piping are not adequately supported pump assembly will be strained See Installation 2 Do not mount the pump on a wooden platform Securely mount on a concrete platform for quietest performance before working on pump or motor ...

Страница 8: ...which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damage to associated equipment cost of capital cost of substitute p...

Отзывы: