Filter Maintenance
Filter Maintenance Diagrams
Outlet
Impeller Well
MONTHLY
1. Turn the power off. Unplug both power leads.
2. Remove the
Light Unit
from the aquarium.
Place it somewhere safe away from water and
where it will not be broken / damaged.
3. Place the towel on the floor in front of the
aquarium to guard from water spillage.
4. Move the gravel away from the
Power Head
.
5. Disconnect the
Outlet
from the top of the
Power Head
and remove it.
6. Place one hand on the gravel to stop the
Under Gravel Filter Plate
from moving. With
your other hand gently lift the
Power Head
from
the aquarium.
DO NOT LET ANY GRAVEL GO
DOWN THE UP LIFT RISER.
7. Place the
Power Head
and
Outlet
in a bucket
and take them to the sink.
8. Pull the
Impeller Cap
off the bottom of the
Power Head
, this will uncover
Impeller
.
9. Grasp the
Impeller Blades
and remove from
the
Impeller Well
.
10. Use a double ended pipe brush to clean
Impeller
and inside of
Impeller Well
.
11. Also run a pipe brush through the
Outlet
.
12. Reconnect all parts and place the
Power
Head
back into the aquarium.
13. Push the gravel back around the
Power
Head
.
14. Ensure the power lead is not wet and plug it
back in.
15. Turn the power back on and check that
water is flowing though the
Outlet
.
16. Replace the
Light Unit
.