9

Installation 105/106

All Aqua One Maxi Power Heads come fully 

assembled and are ready to use.

1. The 105 and 106 power heads come 

supplied with 1 x 21mm inlet adapter and 1 x 

19mm outlet adapter.

a) If no attachment is required simply place 

the power head in the aquarium and fasten to 

the glass using the suction cups.

b) If the power head is to be used in a sump 

attach the 19mm outlet and use 19mm hose 

to run from the outlet of the pump to the 

aquarium.  For  extra  security  a  good  quality 

stainless steel clamp should be used to secure 

the hose to the outlet.

c) If the power head is to be used to run an 

under  gravel  filter  remove  the  pre  filter  and 

attach the 21mm inlet adapter to the base of 

the power head, then sit the power head in 

the aquarium with the inlet attached to the 

up lift of the under gravel filter and attach the 

power head to the wall of the aquarium with 

the suction cups.

Maintenance 105/106

Clean the impeller at least once a month.

Refer to the “Know You Filter” page for help 

with the following procedure.

1. Remove the power head from the aquarium 

and take it to the sink.

2. Grasp the motor with one hand and the pre 

filter with the other and gently pull apart.

3. Turn the lock anti clock wise to remove then 

pull the impeller cover off to gain access to the 

impeller.

4. Pull impeller from the motor and rinse 

properly. Use an Aqua One double ended pipe 

brush to clean the impeller and the impeller 

well and also any of the outlet options that are 

being used.

5.  Put  the  power  head  back  together  and 

return to the aquarium. Ensure your hand is 

not wet, plug in at the power supply and turn 

on.

Fig 1

Fig 2

Fig 3

Fig 4

Содержание Maxi 101

Страница 1: ...Maxi Powerheads 101 106 Instruction version 18 03 2015 www aquaone com au 2 1 Marine Tropical Coldwater ...

Страница 2: ...wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully ...

Страница 3: ...antee service is required Carefully unpack the product making sure you keep all the packing material until all the parts of the product have been found and the product has been assembled Correct Positioning in Aquarium Set the powerhead up within the arrows indicated above The Powerhead must not be out of the water and must not be in contact with any substrate This product is shipped to you in a f...

Страница 4: ...art you require Alternatively you will find these numbers on the silver label located on the product 101 Impeller 1I 102 Impeller 26I Know Your Power Head 101 102 1 Motor 2 Flow Controller 3 Impeller 4 Impeller Cover 5 Mounting Bracket Pre Filter 6 13mm Outlet 7 13 9mm Reducer 8 Venturi Outlet 9 Venturi Air Line Aqua One Spare Parts 1I 1 2 3 4 9 8 7 6 5 ...

Страница 5: ...e spare part you require Alternatively you will find these numbers on the silver label located on the product 103 Impeller 27I 104 Impeller 28I Know Your Power Head 103 104 1 Motor 2 Impeller 3 Impeller Cover with Flow Controller 4 Mounting Bracket Pre Filter 5 16mm Outlet 6 Venturi Outlet 7 Venturi Air Line Aqua One Spare Parts 1I 1 2 3 4 7 6 5 ...

Страница 6: ... for the spare part you require Alternatively you will find these numbers on the silver label located on the product 105 Impeller 29I 106 Impeller 30I Know Your Power Head 105 106 1 Motor 2 Mounting Bracket 3 Impeller 4 Impeller Cover 5 Lock 6 Pre Filter 7 21mm Inlet Hosetail 8 19mm Outlet Hosetail Aqua One Spare Parts 1I 1 2 3 4 8 7 6 5 ...

Страница 7: ...the flow Remember the more flow the better Maintenance 101 102 Clean the impeller at least once a month Refer to the Know You Filter page for help with the following procedure 1 Remove the power head from the aquarium and take it to the sink 2 Graspthemotorwithonehandandmounting bracket with the other and gently pull apart 3 Remove the impeller cover to gain access to the impeller 4 Pull impeller ...

Страница 8: ...the flow Remember the more flow the better Maintenance 103 104 Clean the impeller at least once a month Refer to the Know You Filter page for help with the following procedure 1 Remove the power head from the aquarium and take it to the sink 2 Graspthemotorwithonehandandmounting bracket with the other and gently pull apart 3 Remove the impeller cover to gain access to the impeller 4 Pull impeller ...

Страница 9: ... sit the power head in the aquarium with the inlet attached to the up lift of the under gravel filter and attach the power head to the wall of the aquarium with the suction cups Maintenance 105 106 Clean the impeller at least once a month Refer to the Know You Filter page for help with the following procedure 1 Remove the power head from the aquarium and take it to the sink 2 Grasp the motor with ...

Страница 10: ...rine Model Maxi 102 Dimensions 6 5x4 5x6 5cm Maximum Flow Rate 500L hr Max Head Height 1 05m Power Requirements 220 240V AC Power Consumption 8W Suitable Cold water Tropical Marine Model Maxi 103 Dimensions 10x6x8cm Maximum Flow Rate 1200L hr Max Head Height 1 2m Power Requirements 220 240V AC Power Consumption 15W Suitable Cold water Tropical Marine Model Maxi 104 Dimensions 11 5x7 5x9 5cm Maximu...

Страница 11: ... on the applicable Aqua One website refer below 2 3 Upon receipt and acceptance of the questionnaire Aqua One will forward by way of email a Certificate of Extended Guarantee to the purchaser 2 4 For more information on how we collect hold use and disclose personal information provided to us please refer to our Privacy Statement on the Aqua One websites or write to our Privacy Officer in your coun...

Страница 12: ...12 Inspiring Excellence in Fish Care ...