Aqua One Cleaview 100 Скачать руководство пользователя страница 6

6

Installation

Clearview 75-100

1.  Remove  the  filter  lid  to  access  the  filter 

body.

2. Place the inlet u-pipe into position. The 

longer side of the pipe sits on the outside of 

the filter body. The shorter side locks into the 

impeller housing.

3.The extension tube then connects to the 

inlet u-pipe. The strainer then attaches to the 

extension tube. The strainer and extension 

tube is the part that sits in the water of the 

aquarium.

4.  Wash  the  carbon  cartridge  in  tap  water 

before use. DO NOT USE DETERGENT OR 

SOAP.  The  carbon  cartridge  slides  into  the 

furthest grooves with the wool

facing the rear of the filter.

(refer to the Diagram on the previous page)

5. The sponge slides in between the cartridge 

and the front of the filter.

6.  Push  the  adjusting  wheel  into  the  bottom 

of  the  filter  body.  This  is  used  to  keep  the 

whole filter level from top to bottom, otherwise 

the  filter  will  slant  away  at  the  top  and  may 

overflow if the filter

cartridge becomes blocked.

7.  Hang  the  filter  off  the  back  wall  of  the 

aquarium with the extension tube and strainer 

inside the aquarium water.

8. Fill the filter body with aquarium water until 

it overflows back into the aquarium. Turn on at 

the power supply. It may take a little while to 

start as it expels the air from the impeller.

9. Adjust  the  flow  with  the  knob  on  the  top 

of the inlet u-pipe. It is better to leave at full 

flow but if this current is too strong, turn down 

slightly.

10. Place the lid back on the filter body.

Clearview 200-800

1. Remove the filter dust cover to access the 

filter body.

2. Place the inlet u-pipe into position. The 

longer side of the pipe sits on the outside of 

the filter body. The shorter side locks into the 

impeller housing.

3. Extend the extension tube from the longer 

side of the inlet u-pipe.

4. The strainer then attaches to the extension 

tube.

5.  Wash  the  carbon  cartridge  in  tap  water 

before use. DO NOT USE DETERGENT OR 

SOAP.  The  carbon  cartridge  slides  into  the 

furthest grooves with the wool

facing the rear of the filter. (refer to the Diagram 

on the previous page)

6. The biogrid slides in between the cartridge 

and the front of the filter.

7.  Hang  the  filter  off  the  back  wall  of  the 

aquarium with the extension tube and strainer 

inside the aquarium water.

8. Fill the filter body with aquarium water until 

it overflows back into the aquarium.

9. Turn on at the power supply. It may take a 

little while to start as it expels the air from the 

impeller.

10. Adjust the flow with the knob on the top 

of the inlet u-pipe. It is better to leave at full 

flow but if this current is too strong, turn down 

slightly.

11.  Place  the  dust  cover  back  on  the  filter 

body.

Содержание Cleaview 100

Страница 1: ...Cleaview 75 100 200 280 300 500 800 Instruction version 19 03 2015 www aquaone com au 2 1 Marine Tropical Coldwater ...

Страница 2: ...wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully ...

Страница 3: ...ton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the number listed below for the spare part you require Alternatively you will find these numbers on the silver label locat...

Страница 4: ...er Body 7 Impeller 8 Adjusting Wheel 9 Extension Tube 10 O ring 11 Motor 12 Strainer 1 2 3 4 5 6 7 8 9 10 11 12 Clearview 100 1 Dust Cover 2 Carbon Cartridge 3 Flow Controller 4 Sponge 5 Inlet U Pipe 6 Filter Body 7 Impeller 8 Extension Tube 9 O ring 10 Motor 11 Strainer 1 2 3 5 4 7 6 8 9 10 11 Clearview 75 ...

Страница 5: ... Filter 200 800 1 Dust Cover 2 Flow Controller 3 Inlet U Pipe 4 Carbon Cartridge 5 Biogrid 6 Extension Tube 7 Strainer 8 Filter body 9 Impeller 10 O ring 11 Motor 1 2 3 4 5 6 7 8 9 10 11 Clearview 200 300 500 800 ...

Страница 6: ...e while to start as it expels the air from the impeller 9 Adjust the flow with the knob on the top of the inlet u pipe It is better to leave at full flow but if this current is too strong turn down slightly 10 Place the lid back on the filter body Clearview 200 800 1 Remove the filter dust cover to access the filter body 2 Place the inlet u pipe into position The longer side of the pipe sits on th...

Страница 7: ...e sink 3 Throw away the carbon cartridge and replace with a new one Wash the new cartridge in tap water before use 4 Remove the entire inlet u pipe Grasp the motor and twist anti clockwise then gently pull down to completely remove it from the filter body 5 Remove the impeller from the motor and wash Use a double ended pipe brush and clean the impeller well Where the impeller sits 6 Use an aquariu...

Страница 8: ...hr Max Aquarium Volume 40L Power Requirements 220 240V AC Power Consumption 3W Suitable Cold water Tropical Marine Model Clearview 200 Maximum Flow Rate 200L hr Max Aquarium Volume 60L Power Requirements 220 240V AC Power Consumption 3 5W Suitable Cold water Tropical Marine Model Clearview 280 Maximum Flow Rate 280L hr Max Aquarium Volume 80L Power Requirements 220 240V AC Power Consumption 4W Sui...

Страница 9: ...on the applicable Aqua One website refer below 2 3 Upon receipt and acceptance of the questionnaire Aqua One will forward by way of email a Certificate of Extended Guarantee to the purchaser 2 4 For more information on how we collect hold use and disclose personal information provided to us please refer to our Privacy Statement on the Aqua One websites or write to our Privacy Officer in your count...

Страница 10: ......

Страница 11: ......

Страница 12: ...12 Inspiring Excellence in Fish Care ...

Отзывы: