Aqua One Arctic 1/6HP Скачать руководство пользователя страница 5

7

GB

CONTROL PANEL DOES NOT COME ON

1. Check the chiller is plugged in.

2. Check the switch is in the “on” position.

3. Unplug the unit. Unscrew the fuse on the chiller and 

verify  that  it  is  not  blown.  Replace  if  necessary.  The 

fuse is located beneath the power cable and the power 

switch in the location shown below.

THE  CHILLER  IS  NOT  COOLING  THE 

WATER OR NOT COOLING ADEQUATELY

1. The  chiller  is  not  placed  in  an  area  with 

sufficient 

ventilation.  Ensure  the  air  intake  and  outlets  are  not 

obscured.

2.  The  radiator  needs  to  be  cleaned.  Refer  to 

maintenance instructions.

3.  The  set  temperature  is  higher  than  the  water 

temperature. Check the set temperature and adjust if 

necessary.

4. The water 

flow

 is too slow or too fast. Ensure 

flow

 rate 

through the chiller is as per the recommendations.

THERE  IS  NOISE  COMING  FROM  THE 

CHILLER UNIT

1. The chiller is not placed on a level surface.

2.  The  noise  is  being  caused  by  vibrations  due  to 

objects  sitting  on  or  leaning  against  the  unit.  Ensure 

nothing is in direct contact with the chiller.

AN  ALARM  IS  SOUNDING  AND  THE 

DISPLAY IS FLASHING

1.  If  the  display  is 

flashing

  “LLL”  the  temperature  is 

below  the  minimum  operating  temperature  (0°C). 

Switch  the  unit  off  until  air  temperature  is  above  this 

temperature.

2. If the display is 

flashing

 “HHH” the temperature is 

above  the  maximum  operating  temperature  (50°C). 

Switch the unit off, check for obstructions around the air 

intake/outlets. The unit will not operate if air temperature 

is above the maximum operating temperature.

Trouble Shooting

Specifications

Chiller Model: 

Arctic 1/6HP

Dimensions: 

39x32x46cm

Max

 

Aquarium 

Volume: 

300L

Flow Rate:

 800-2200L/hr

Inlet/Outlet Size:

 19mm

Power Requirements:

 220 ~ 240V

Power: 

1/6HP

Refrigerant: 

R134A

Suitable:

 Marine

Chiller Model: 

Arctic 1/3HP

Dimensions: 

46x39x52cm

Max

 

Aquarium 

Volume: 

650L

Flow Rate:

 1200-3600L/hr

Inlet/Outlet Size:

 19mm

Power Requirements:

 220 ~ 240V

Power: 

1/3HP

Refrigerant: 

R134A

Suitable:

 Marine

Chiller Model: 

Arctic 3/5HP

Dimensions: 

48x52x52cm

Max

 

Aquarium 

Volume: 

1000L

Flow Rate:

 1800-4800L/hr

Inlet/Outlet Size:

 19mm

Power Requirements:

 220 ~ 240V

Power: 

3/5HP

Refrigerant: 

R134A

Suitable:

 Marine

switch

cable

fuse

Disposal

 of 

used

 

Electrical

 & Electronic Equipment 

(Applicable

  in  the 

European

  Union 

and

  other 

European

 

countries

  with 

separate

  collection 

systems)

This  symbol  on  the  product  or  on  its 

packaging  indicates  that  the  product 

must  not  be  disposed  of  with  normal 

household  waste.  Instead,  it  is  your 

responsibility  to  dispose  of  your  waste 

equipment  by  arranging  to  return  it  to  a  designated 

collection  point  for  the  recycling  of  waste  electrical 

and electronic equipment. By separating and recycling 

your waste equipment at the time of disposal you will 

help to conserve natural resources and ensure that the 

equipment is recycled in a manner that protects human 

health  and  the  environment.  For  more  information 

about recycling this product, please contact your local 

city 

office,

  your  household  waste  disposal  service  or 

the shop where you have purchased the product.

Содержание Arctic 1/6HP

Страница 1: ...Arctic Chiller Inspiring Excellence in Fish Care www aquaone com au 1 6HP 1 3HP 3 5HP Instruction version 13 10 2010 ...

Страница 2: ...ppliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully to disconnect 7 Do not ...

Страница 3: ...ts of the product have been found and the product has been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection 1 Place the unit on a level surface 2 Allow adequate ventilation Allow sufficient clearence to the front and sid...

Страница 4: ...lug has been disconnected It is recommended to clean the intakes on the chiller once a month Failure to do so may cause the chiller to overheat and suffer permanent damage In order to clean the unit remove the plastic covers then using a soft bristled brush throughly brush the entire grill Vacuum the area to remove any dust dirt that has come loose CAUTION When cleaning the chiller do not use wate...

Страница 5: ...utlets The unit will not operate if air temperature is above the maximum operating temperature Trouble Shooting Specifications Chiller Model Arctic 1 6HP Dimensions 39x32x46cm Max Aquarium Volume 300L Flow Rate 800 2200L hr Inlet Outlet Size 19mm Power Requirements 220 240V Power 1 6HP Refrigerant R134A Suitable Marine Chiller Model Arctic 1 3HP Dimensions 46x39x52cm Max Aquarium Volume 650L Flow R...

Страница 6: ...try of purchase 2 5 Where Aqua One determines goods are being used in a manner contrary to the instructions specifications or this Guarantee Aqua One reserves the right to terminate Extended Guarantee for such goods and will provide written notice to the purchaser 3 0 Exclusions and Limitations Where permitted by local law the following exclusions and limitations apply in regard to Guarantee 3 1 G...

Отзывы: