Aqua Medic aCone 1.5 Скачать руководство пользователя страница 9

 

Type   

Outlet 
height 

Total height  
(lower edge) 

Venturi 
pump  

Power 
consumption  

Capacity  

 

aCone 1.5 

 

 
24.5 cm 

 
53.0 cm 

Eco Runner 
3700 incl. air 
wheel 

 
38 Watt 

 
up to 1,500 l 

 

aCone 3.0 

 
25.5 cm 

 
59.5 cm 

Eco Runner 
6000 incl. air 
wheel 

 
54 Watt 

 
up to 2,500 l 

 

2. Principle of operation  

 
The skimmer with venturi pump has to be placed in a separate filter tank. The water is pumped to 
the skimmer by the venturi pump. The pump draws water from the filter tank and mixes it with air. 
Within the pump housing, the bubbles are cut into very fine pieces by the Aqua Medic 

air wheel

The  air/water  mixture  is  pumped  back  into  the  skimmer.  The  treated  water  flows  through  the 
outlet or drain valve out of the skimmer back into the filter tank.  

 
3. Venturi pump 
 

The

  Eco  Runner 

series  of  magnetically  coupled  centrifugal  pumps  are  very  quiet  in  operation. 

They have fully encapsulated synchronous motors. All materials are salt water resistant.  
 
The polished ceramic shaft and bearing is practically wear-resistant, ensuring a long operating life. 
An  integrated  thermal  overheat  protection  device  prevents  damage  to  the  windings  should  the 
impeller rotation be impeded. The polished ceramic shaft and bearing is practically wear-resistant, 
ensuring a long operating life. An integrated thermal overheat protection device prevents damage 
to the windings should the impeller rotation be impeded. 
 
The  pumps  can  easily  be  taken  apart  for  cleaning.  The  direction  of  the  rotation  is  controlled 
electronically. This enables a very efficient operation. 
 

3.1. Technical data         
 

Type 

Eco Runner 6000 incl. air 
wheel 

Eco Runner 3700 incl. air 
wheel 

Voltage: 
Power consumption: 

230 V~/50 Hz 
54 Watt 

230 V~/50 Hz 
38 Watt 

Cable length: 
Protection class:  
Protection rating: 

3 m 

IP X8 

3 m 

IP X8 

Max. depth: 

1 m ,      

  

             1 m 

1 m ,      

  

             1 m 

Max. water temperature: 

35 °C 

35 °C 

 
3.2. Connections

 

 
Suction side:

 The included air injection nozzle is at the pump’s suction side.   

 

Pressure  side:

 The pressure side can be connected with the skimmer by the existing connection 

with union nut (13). Please make sure that the O-ring (7) was placed into the groove.  
 
 
 
 
 
 
 
 
 

Содержание aCone 1.5

Страница 1: ...ein Qualitätsgerät entschieden Es ist speziell für den aquaristischen Gebrauch entwickelt und von Fachleuten erprobt worden Mit diesem Gerät sind Sie bei richtiger Anwendung in der Lage die organischen Inhaltsstoffe Ihres Aquarienwassers wirksam zu entfernen AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Germany __________________________________________________________________________________...

Страница 2: ... für Dispergatorpumpe Ablaufschlauch mit Hahn für Schaumtopf Abb 1 aCone 1 5 Abb 2 aCone 3 0 aCone 1 5 und 3 0 1 Reaktionsrohr 10 O Ring Auslaufrohr 2 Schaumtopf 11 Auslaufrohr 3 Schaumtopfdeckel 12 Bodenplatte abschraubbar 4 Schalldämpfer 13 Pumpenanschluss 5 Schlauchanschluss Schalldämpfer 14 Ablasshahn 6 Regulierschraube 15 Dispergatorpumpe 7 O Ring Dispergatorpumpe 16 Schlauchanschluss Schaumt...

Страница 3: ... besondere Laufruhe aus Sie besitzen einen voll gekapselten Synchronmotor Alle Materialien sind meerwasserbeständig Die Keramikwelle und das Keramiklager im Inneren der Pumpe sind praktisch verschleißfrei und bieten Gewähr für eine lange Lebensdauer Der gesamte Pumpenteil kann demontiert und gereinigt werden Alle elektrischen Teile der Pumpe sind gekapselt Die Drehrichtung der Pumpe wird elektroni...

Страница 4: ...rschluss am Kreiselgehäuse geöffnet werden Die Läuferbaugruppe s Abb 3 Nr 3 lässt sich jetzt herausziehen Vorsicht Das Teil sitzt relativ fest und darf beim Hinausziehen nicht verkantet werden Die Achse könnte dabei zerbrechen Sie kann unter fließendem Wasser gereinigt und wieder eingebaut werden Wenn der Rotor komplett ausgebaut ist müssen auch die Löcher in der Abdeckplatte Abb 4 gereinigt werde...

Страница 5: ...ergatorpumpe startet Dazu den unteren Ablasshahn 14 zunächst komplett öffnen Bei hoher Wasserbelastung kann der Hahn auch komplett heraus geschraubt werden Bleibt der Wasserstand konstant schließt man ihn nur so weit bis der Abschäumer halb bis zweidrittel gefüllt ist Danach wartet man einige Zeit und nimmt die Feineinstellung am besten ein zwei Stunden später mit der oberen Regulierschraube vor E...

Страница 6: ...oder das Kreiselgehäuse bzw Air Wheel verschmutzt Maßnahme Dispergatorpumpe abmontieren gründlich reinigen Lufteinzugsdüse mit dünnem Stäbchen oder Bürste reinigen und Pumpe wieder anschließen Problem Der Abschäumer schäumt zu stark ab Der Schaumtopf ist zu schnell gefüllt Ursache Der Wasserstand im Filterbecken ist nicht optimal Maßnahme Wasserstand korrigieren Ursache Der Wasserstand im Abschäum...

Страница 7: ...e of this protein skimmer you have selected a top quality product It has been specifically designed for aquarium use and tested by professionals This unit will effectively remove organic substances from your aquarium water AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Germany _________________________________________________________________________________________ ...

Страница 8: ... discharge hose incl valve for foam cup Fig 1 aCone 1 5 Fig 2 aCone 3 0 aCone 1 5 and 3 0 1 Reaction pipe 10 O ring of outlet pipe 2 Foam cup 11 Outlet pipe 3 Lid for foam cup 12 Bottom plate unscrewable 4 Sound absorber 13 Pump connection 5 Hose connection of the 14 Drain valve sound absorber 15 Venturi pump 6 Adjusting screw 16 Hose connection of the foam cup 7 O ring of venturi pump 17 O ring o...

Страница 9: ...ramic shaft and bearing is practically wear resistant ensuring a long operating life An integrated thermal overheat protection device prevents damage to the windings should the impeller rotation be impeded The polished ceramic shaft and bearing is practically wear resistant ensuring a long operating life An integrated thermal overheat protection device prevents damage to the windings should the im...

Страница 10: ...ions and undo the bayonet on the pump housing Now the impeller assembly Fig 3 can be taken out Caution This part is tight fit and must be removed carefully so as not to break the ceramic shaft It can be cleaned under running water and then re assembled If the rotor is completely dismounted also the holes in the cover plate Fig 4 have to be cleaned They provide for sufficient water cooling of the r...

Страница 11: ...ve Fig 1 and 2 No 14 completely With high water load the valve can also be unscrewed completely If the water level remains constant it has to be closed only so far until the skimmer is filled to half or two thirds Afterwards wait for some time and make the fine adjustment with the upper adjusting screw best one to two hours later A water level too high leads to very fast overflowing of the foam cu...

Страница 12: ...he date of purchase AB Aqua Medic GmbH undertakes to repair or at our option replace the defective part free of charge always provided the product has been installed correctly is used for the purpose that was intended by us is used in accordance with the operating instructions and is returned to us carriage paid The warranty term is not applicable on the all consumable products Proof of Purchase i...

Страница 13: ... à celui d un appareil de qualité Il a été spécialement conçu pour l usage aquariophile et testé par les professionnels L utilisation correcte de cet appareil vous permet de retirer les substances organiques de l eau de votre aquarium AB Aqua Medic GmbH Gewerbepark 24 49143 Bissendorf Allemagne _________________________________________________________________________________________ ...

Страница 14: ...uyau d écoulement avec robinet pour récipient à écume Schéma 1 aCone 1 5 Schéma 2 aCone 3 0 aCone 1 5 et 3 0 9 Tuyau à réaction 10 Joint tuyau écoulement 10 Récipient à écume 11 Tuyau écoulement 11 Couvercle récipient à écume 12 Plaque de fond dévissable 12 Silencieux 13 Raccord pompe 13 Raccord tuyau silencieux 14 Robinet vidange 14 Vis de régulation 15 Pompe Dispergator 15 Joint pompe Dispergato...

Страница 15: ...ement particulièrement silencieux Les pompes possèdent un moteur synchrone entièrement encapsulé Tous les matériaux sont résistants à l eau de mer L axe et le roulement en céramique à l intérieur de la pompe sont pratiquement sans usure et garantissent une longue durée de vie L ensemble des éléments de la pompe peut être démonté et nettoyé Tous les éléments électriques de la pompe sont encapsulés ...

Страница 16: ...fermeture à baïonnette du corps de pompe Le groupe rotor voir schéma 3 peut être retiré Attention la pièce est positionnée de façon relativement serrée et lors du retrait il ne faut pas l incliner L axe pourrait se briser Il peut être nettoyé sous l eau courante et de nouveau remis en place Lorsque le rotor est complètement démonté il faut aussi nettoyer les trous de la plaque de fermeture voir sc...

Страница 17: ...emplit l écumeur en démarrant la pompe Dispergator Pour cela il faut ouvrir complètement le robinet de vidange schéma 1 et 2 N 14 inférieur Lors d une charge d eau élevée le robinet vidange peut être aussi vissé complètement dehors Lorsque le niveau d eau reste constant on le ferme de façon à ce que l écumeur soit rempli à moitié ou au 2 3 On attend ensuite un peu et on procède au réglage fin deux...

Страница 18: ...a pompe Dispergator la nettoyer soigneusement nettoyer la buse d aspiration d air avec une fine baguette puis de nouveau raccorder la pompe Problème L écumeur écume trop Le récipient à écume se remplit trop vite Cause Le niveau d eau du bac de filtration n est pas optimal Mesure Corriger le niveau d eau Cause Le niveau d eau dans l écumeur est trop élevé Mesure Comme décrit dans le 4 réguler le ni...

Отзывы: