![Aqua Lung MRS III Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/aqua-lung/mrs-iii/mrs-iii_operation-and-maintenance_2958572007.webp)
1.0 DESCRIPTION OF UNIT:
The MRS III is designed to refill the Aqua Lung Survival Egress
Air (SEA) LV, MK1.5, MK2, MK2.5. It has an internal supply of two carbon fiber composite
4500psi cylinders and has two preset regulated 3000psi fill lines. The control panel will allow
you to monitor the pressure in the supply cylinders, verify the preset regulated pressure and con-
trol the filling of one or two SEA units.
2.0 CONFIGURATION:
The attached picture shows the COMPLETE MRS III UNIT. The items
lettered are listed below.
MRS III
Mobile Refill System
A. Supply Cylinder (CYL1)
B. Refill Port w/ rubber cap (RCAP)
C. Adapter PRS6 to CGA 347
D. Case (1650)
E. Frame/Control Panel (FRM1)
F. SEA fill adapter (PRS21)
G. Bleeder valves (712)
H. Fill Hose (HOS1)
I. SEA Fill pressure Gauge (GAG1)
J. Supply Pressure Gauge (GAG1)
K. Preset regulator (1120)
L. Regulated Pressure Gauge (GAG1)
M. Fastener for top cover of the frame
N. Top Cover/ Instruction sheet
O. Fill Valves (YVA3010A)
P. Supply Cylinder Valves (VAL1)
Q. SEA Cylinder Holder/Burst Protector
R. Unit/serial number, Manufacture date
figure 1
MRS III
N
O
P
B
K
L
H
D
Q
E
I
O
A
A
F
G
F
J
R
M
M
Q
C
NOTE:
These identification letters do not match the I.D. numbers in the PARTS section, page 25
page 1
Содержание MRS III
Страница 6: ......
Страница 30: ...Illustrated Parts Breakdown Mobile Refill System III 100701 FRONT OF UNIT page 24...
Страница 31: ...SIDE VIEW page 25...
Страница 43: ...MRS III FLOW DIAGRA M page 37...
Страница 44: ...page 38...
Страница 45: ...page 39...