Procedure A 

Cleaning and Lubricating 

(All Aqualung Regulators) 

 

 
 

Cleaning brass and stainless steel parts.  

 

1.  Pre-clean by soaking in NETALU diluted to 25%. 
2.  Cleaning in an ultra-sonic bath filled with a mixture of washing-up  hot water.  If some resistant deposits remain 

then fill the ultrasonic bath with white vinegar and repeat.  DO NOT put plastic, rubber, silicone or anodised aluminium 
parts in contact with vinegar.    

3.  Rinse in demineralised or fresh water to avoid calcium deposits. Soak for 10 minutes. Dry with filtered low pressure air and 

then check that their condition is now suitable for re-use.   

 

Cleaning plastic, rubber and anodised aluminium parts.  
 

For anodised aluminium parts: soak in a « NETALU diluted to 25% ». Rinse in fresh water and dry with low-pressure filtered air.    
For plastic parts. (casings, plugs.): clean in an ultrasonic bath containing a mixture of washing-up liquid and hot water. Use only a 
toothbrush with nylon bristles to remove any deposits.    Rinse in fresh water and dry with low-pressure filtered air 
 

 

 

Cleaning parts for Nitrox/O2 use.  

 

1.  Metal parts: Pre-clean by soaking in NETALU diluted to 25%. 
2.  Ultrasonic cleaning in Promoclean TP108 diluted at 5%. 
3.  Rinse in demineralised water. Soak for 10 min.  
4.  Dry in the open air in a clean and dust-free atmosphere.  Place the parts on a white cloth, allow to dry and check after 

drying that the cloth shows no grease deposits and that the condition of the parts is appropriate for re-use with Nitrox/O2. 

 

Cleaning hoses.  

 
If there is significant corrosion then it is permissible to soak only the ends in an ultrasonic bath, avoiding any possibility of the 
solution entering the hose. Rinse in fresh water and allow to dry with the connections hanging down. Dry the inside with filtered 
compressed air before reconnecting the hose to the regulator. 
 
 

Wiping.  

 
To wipe parts, use a white filter paper, a pure cotton cloth or any other material that 

does not produce fluff

.

   

 

Inspection.  

 
Visually check under a white light (day light or artificial light).  
The parts are completely free of any traces of:  
 

1.  organic materials (oil, grease, paint, rust…) 
2. cleaning 

agents 

3. dust 
4. humidity 

 
 

Lubrication.  

 
When handling O-rings wear unpowdered latex gloves. It is important not to allow contact between the internal components and the 
skin or any other source of contamination when the regulator is being prepared for Nitrox use. All seals should be lubricated with 
Cristolube MCG111.   Cover the seals with a light film of grease and remove any excess by rolling the seal between finger and 
thumb. Do not use an excess of grease; this can have the effect of accumulating particles that could damage the O-rings. 
 
 

Attention: Do not place plastic and rubber parts in contact with acid solutions.  This could alter their physical 
properties and cause degradation and premature breakdown.  

Содержание Mistral Mouthpiece

Страница 1: ...SERVICE MANUAL MISTRAL MOUTHPIECE Copyright 2005 Aqualung France 2005 ...

Страница 2: ... INSTRUCTIONS 3 GENERAL CONVENTIONS 3 DISASSEMBLY PROCEDURE 4 REASSEMBLY PROCEDURE 5 TEST IN WATER 7 Table 1 Troubleshooting guide 8 Table 2 List of tools and service kits 9 Table 3 Recommended cleaners and lubricants 10 Procedure A Cleaning and Lubricating 11 Maintenance Notes 12 Exploded views of Mistral mouthpiece 13 ...

Страница 3: ...he tool 116230 into the HP port and then grip the tool with the vice 4 Once the regulator has been disassembled the re usable components should be separated from the components that need to be replaced Fragile items with seats or crowns with critical sealing surfaces should be separated and protected during servicing in order to prevent any damage 5 Use only spare parts from Aqualung service kits ...

Страница 4: ...g the cam with your thumb then remove the mouthpiece Note Before commencing disassembly consult the exploded view to check the reference numbers of all parts requiring replacement These parts should all be replaced by new parts and should not be re used on the pretext that the regulator has seen little use since its manufacture or since its last service Attention Use only the special tool when rem...

Страница 5: ...re assemble the regulator make sure that all replacement parts have been cleaned and lubricated in accordance with Procedure A Cleaning and Lubricating on page 14 RE ASSEMBLY PROCEDURE 1 If the valves have been extracted pass the tail through the hole in the valve holder and pull gently on it until the shoulder passes through to the inside of the valve holder If the valve is new then cut the exces...

Страница 6: ...tion If they are in good condition it is not necessary to replace them and they can be reused If they show any signs of deterioration they should be replaced and refitted following the procedure described in the Mistral Second Stage Service Manual 13 Place the corrugated hoses onto the connectors and proceed as follows a Fit the corrugated hoses to the connectors Note Check that the connectors are...

Страница 7: ... the hoses completely in water to check that there are no leaks When you are sure that there is no leak close the cylinder valve and purge the regulator Remove the first stage from the cylinder and refit the dust cap If a leak has been detected then note its source and refer to Table 1 Troubleshooting Guide Note Do not mistake any bubbles that are trapped in the regulator with a leak If there is a...

Страница 8: ...ing resistance in the complete regulator 4 The cylinder is empty 4 Charge the cylinder 1 The valve holders have been fitted the wrong way round in the mouthpiece 1 Disassemble and refit following the correct procedure 2 The mouthpiece has been fitted backwards to the corrugated hoses 2 Disassemble and refit following the correct procedure 3 The cylinder valve is not open 3 Open the valve Impossibl...

Страница 9: ...e support disassembly 109436 N C O ring tool Fit and remove O rings 944022 N C Tightening collar tool PANDUIT GS4H Tightening collars PLT4H N a N C Collar cutting pliers Removing tightening collars N a 125905 Service Kit MISTRAL All versions except Nitrox N a 125936 Service Kit MISTRAL Nitrox O2 Nitrox Version N a ...

Страница 10: ...g brass and stainless steel parts Household stores Washing up liquid diluted with hot water Degreases brass and stainless steel parts general cleaning of plastic and rubber parts Household stores Attention Silicone parts do not require lubrication Do not grease them Greasing silicone parts can change their molecular construction and cause premature degradation of the material Attention Do not use ...

Страница 11: ...rts on a white cloth allow to dry and check after drying that the cloth shows no grease deposits and that the condition of the parts is appropriate for re use with Nitrox O2 Cleaning hoses If there is significant corrosion then it is permissible to soak only the ends in an ultrasonic bath avoiding any possibility of the solution entering the hose Rinse in fresh water and allow to dry with the conn...

Страница 12: ...12 Mistral Mouthpiece Service Manual Maintenance Notes ...

Страница 13: ...F I R S T T O D I V E 13 Exploded view of Mistral mouthpiece 125910 ...

Страница 14: ...1ere Avenue 14e rue BP 148 06513 CARROS cedex France 00 33 0 4 92 08 28 88 FAX 00 33 0 4 92 08 28 99 ...

Отзывы: