27. Ensure that the adjustment screw is turned completely

counter-clockwise into the retaining sleeve, and fit the cap
nut(31) over its end.  While holding the adjustment screw
secure, thread the cap nut clockwise onto the end of the valve
body until flush with the box bottom.  Apply a torque wrench
with 

2

" hex socket to tighten the cap nut until it is flush

against the box bottom, to a torque measurement that does not
exceed 24 inch-pounds.

28. Apply a medium blade screwdriver to turn the adjustable

crown counter-clockwise inside the valve body.  Watch
closely as the lever arm begins to rise after 2-3 turns, and
continue to slowly turn the adjustable crown counter-clock-
wise until the top of the lever stands just below the rim of the
box bottom; exactly even with the first thread (see Fig. 22).

CAUTION:  If the lever does not readily engage with the
retaining sleeve inside the valve body, this may indicate that
the retaining sleeve was incorrectly installed.  Disassemble
to correct as needed, and closely inspect the condition of the
retaining sleeve to ensure that the railed channel has not
been damaged as a result of incorrect installation.  If any
signs of damage are found, replace the sleeve with new .
Damage to the lever retaining sleeve may seriously impair
the proper engagement of the lever.

29. Examine the exhaust cover(34) and the box bottom to identify

the locking tabs and grooves of each respective part.  Press
one corner of the exhaust cover onto the box bottom until the
mating tab snaps audibly into place.  Press the center tab next,
followed by the tab of the opposite corner, and check to
ensure that all three are securely locked into their grooves.

30. Install the diaphragm(4) into the box bottom with its raised

center facing up, and check to ensure it is evenly seated onto
the shoulder at the base of the threads.

31. Place the purge cover(3) directly over the diaphragm, and

rotate it as needed to align the logo horizontally straight.

32. Fit the retaining ring(2) down over the purge cover, and apply

one pin of the Circlip/ Retaining Ring Tool (P/N 1078-46) to
a slot in the retaining ring.  While holding the purge cover
securely in place, turn the retaining ring clockwise until it is
lightly snug.  Check to ensure that the purge cover has not
rotated and correct if necessary.  Place the tool directly over
the purge cover with the two pins facing down on each side,
and firmly press straight down to depress the purge cover so
that the pins are securely engaged into two opposite slots of
the retaining ring(2).  While holding the tool securely en-
gaged, turn the retaining ring clockwise to tighten until snug.

33. Thread the color ring(1) onto the box bottom and turn by

hand until snug.

34. Position the adjustment knob(32) over the end of the adjust-

ment screw so that the through holes of both parts are in exact
alignment.  Press the adjustment knob firmly onto the end of

Fig. 22 - Lever Height Preliminary Setting

Содержание Micra ADJ

Страница 1: ...Micra ADJ Second Stage Regulator Copyright 1999 Aqua Lung America Inc Doc No 1008 89 Authorized Dealer SERVICE REPAIR MANUAL...

Страница 2: ...rocedures 10 Final Adjustment Testing Procedures 15 Second Stage Air Flow Test 17 Second Stage Opening Effort Test 17 Second Stage Purge Flow Test 17 External Leak Test 18 Subjective Breathing Test 18...

Страница 3: ...GENERAL GUIDELINES 1 In order to correctly perform the procedures outlined in this manual it is important to follow each step exactly in the order given Read over the entire manual to become familiar...

Страница 4: ...st stage with a stable intermediate pressure of 140 psi 5 with no open ports or hoses 2 Connect the first stage to a cylinder that is filled with 3 000 psi and open the cylinder valve to pressurize th...

Страница 5: ...the mouthpiece 17 from the box bottom Inspect the mouth piece to ensure it is free of any tears or cuts that may cause leakage of water into the second stage or other discomfort Discard the mouthpiec...

Страница 6: ...REVISION A A10 Pull the cap nut off the stem of the adjustment screw and examine closely to ensure that no signs of cracking or other damage are present If damage is found discard the cap nut and rep...

Страница 7: ...ce is felt B13 To remove the lever insert the slotted end of the Lever Removal Installation Tool P N 1008 84 into the adjust ment end of the valve body and rotate the tool slightly until the keyed slo...

Страница 8: ...pt to reuse 22 Using a plastic or brass O ring tool lightly stick the center of the LP seat 23 inside the head of the poppet and lift the seat out being very careful to avoid damaging the poppet Dis c...

Страница 9: ...6 and set it aside 28 Pull the vane adjustment switch out of the box bottom Re move and discard the O ring 15 and set the switch aside 29 Place a medium blade screwdriver approximately 2 inch inside...

Страница 10: ...being positioned inside the box bottom 4 While holding the vane switch in place set the box bottom on a flat surface with the open side facing down and the switch at 12 o clock Guide the tool holding...

Страница 11: ...g down inside Gently place the spring 25 down over the metal shaft of the poppet so that it rests flush over the ribbed head inside the valve body 12 Place the washer 26 down inside the valve body so...

Страница 12: ...he box bottom secure apply a torque wrench with w crow foot to tighten the hex nut snug to a torque measurement of 45 55 inch lb s 18 Before proceeding it is important to become completely familiar wi...

Страница 13: ...stment end of the valve body facing straight up position the retaining sleeve above the opening to align the railed channel of the sleeve with the grooved feature of the lever arm When these two parts...

Страница 14: ...er 34 and the box bottom to identify the locking tabs and grooves of each respective part Press one corner of the exhaust cover onto the box bottom until the mating tab snaps audibly into place Press...

Страница 15: ...the following section titled Final Adjustment Testing Final Adjustment Testing Procedures NOTE Before performing the following procedure refer to Table 5 titled Test Bench Specifications Micra ADJ CA...

Страница 16: ...ntil the airflow has stopped without over adjusting When only a slight amount of airflow is present release the knob of the adjustment tool to ensure that it no longer makes contact with the crown 8 W...

Страница 17: ...imum of 15 SCFM 425 liters per minute The reading on the Magnahelic gauge inhalation exhalation effort gauge should indicate no more than 6 O H2O If the reading exceeds 6 0 H2O refer to refer to Table...

Страница 18: ...assembling to correct any leaks rinse the entire regulator thoroughly with fresh water and blow out all residual mois ture with filtered low pressure 50 psi air Disassemble and remedy the problem refe...

Страница 19: ...Guide 2 Lever 5 not properly engaged with 2 Disassemble and inspect condi retaining sleeve 27 tion of retaining sleeve 3 Crown 12 incorrectly adjusted 3 Reset crown and perform Final lever 5 set too...

Страница 20: ...wrench Hex nut removal installation N A n open end wrench crow foot IP hose fitting N A 2 box wrench hex socket Cap nut 1078 46 Circlip Retaining Ring Tool C clip retaining ring removal installation...

Страница 21: ...full out counterclockwise Slight leak Knob turned in clockwise 2 w turn None Intermediate pressure Inlet 2 500 3 000 100 psi 140 5 psi Intermediate pressure creep Inlet 2 500 3 000 100 psi 5 psi max b...

Страница 22: ...sidue Remove parts from the acid bath and place directly into this rinse Agitate lightly and allow to soak for 5 10 minutes Remove and blow dry with low pressure 25 psi filtered air and inspect closel...

Страница 23: ...kite Products Inc steel and brass parts 50 Valley Road Berkeley Heights NJ 07922 White distilled vinegar Acid bath for reusable stainless Household grade 100 gr steel and brass parts Liquid dishwashin...

Страница 24: ...24 Micra ADJ Second Stage Service Repair Manual 1997 U S Divers Co Inc TECHNICIAN S NOTES...

Страница 25: ...1058 48 Mouthpiece Comfo Snap on Small 17 1058 31 Mouthpiece Snap on Octopus 18 1049 13 Clamp Black 19 8601 37 C Clip 20 8200 46 O ring 21 1008 45 Valve Body 22 1001 32 Pin 23 1085 10 LP Seat 24 1008...

Отзывы: