Doc. 12-7852-r05 (8/5/16)
20
DIVE FEATURES
© Aqua Lung International, Inc. (2016)
BAR GRAPHS
The i750TC features two specific bar graphs.
1. The one on the left represents ascent rate. It is referred to as ASC Bar Graph.
2. The one on the right represents nitrogen loading. It is referred to as the N2 Bar Graph.
Nitrogen Loading
Ascent Rate
ASC BAR GRAPH
The ASC Bar Graph provides a visual representation of ascent speed (i.e., an ascent speedometer). When the
ascent is faster than the recommended 30 fpm (9 mpm), all segments flash until the ascent is slowed.
# OF SEGMENTS ASCENT RATE,
FPM (MPM)
0
0 - 1 (0 - 0.3)
1
>1 - 5 (0.3 – 1.5)
2
>5 - 10 (>1.5 - 3.0)
3
>10 - 15 (>3.0 - 4.6)
4
>15 - 20 (>4.6 - 6.1)
5
>20 - 25 (>6.1 - 7.6)
6
>25 - 30 (>7.6 - 9.1)
7
>30 (>9.1)
N2 BAR GRAPH
The N2 Bar Graph represents your relative No Decompression or Decompression status. As your depth and
elapsed dive time increase, the bar graph will grow in length, shift from green to amber, and ultimately to red (in-
dicating a Decompression condition). As you ascend the bar graph recedes, indicating that additional No Decom-
pression time is available. The i750TC monitors multiple theoretical nitrogen compartments simultaneously. The
N2 Bar Graph displays the one that is in control of your dive at any given time.
ALGORITHM
The i750TC utilizes the Z+ algorithm to calculate nitrogen tissue loading. Performance is based on Bühlmann
ZHL-16C algorithm model. To create even greater margins of safety with respect to decompression, a Conserva-
tive Factor as well as No Decompression Deep and Safety Stops can be included for No Decompression dives.
CONSERVATIVE FACTOR
When the CF is set On, the dive time remaining, No Decompression/O2 MIN, which are based on the algorithm
and used for N2/O2 calculations and displays relating to Plan Mode, will be reduced to the values available at the
altitude level that is 915 m (3,000 ft) higher than the actual altitude at activation. Refer to the charts in the back of
this manual for dive times.
DS (DEEP STOP)
When the DS selection is set ON, it will trigger after descending deeper than 24 m (80 ft. The i750TC then calcu-
lates (continually updating) a Stop Depth equal to
½
the Max Depth.
NOTE: The Deep Stop feature only works in DIVE mode while within No Decompression times.
ASC ALARM TRIGGERED
flashing
Содержание i750TC
Страница 1: ... Aqua Lung International Inc 2016 Dive Computer Owner s Manual Doc 12 7852 r05 8 5 16 i750TC ...
Страница 6: ...Doc 12 7852 r05 8 5 16 6 Aqua Lung International Inc 2016 GETTING STARTED ...
Страница 11: ...Doc 12 7852 r05 8 5 16 11 Aqua Lung International Inc 2016 HOME MENU ...
Страница 18: ...Doc 12 7852 r05 8 5 16 18 Aqua Lung International Inc 2016 DIVE FEATURES ...
Страница 25: ...Doc 12 7852 r05 8 5 16 25 Aqua Lung International Inc 2016 DIVE SURFACE MODE ...
Страница 35: ...Doc 12 7852 r05 8 5 16 35 Aqua Lung International Inc 2016 DIVE OPERATION ...
Страница 47: ...Doc 12 7852 r05 8 5 16 47 Aqua Lung International Inc 2016 GAUGE MODE ...
Страница 52: ...Doc 12 7852 r05 8 5 16 52 Aqua Lung International Inc 2016 FREE MODE ...
Страница 59: ...Doc 12 7852 r05 8 5 16 59 Aqua Lung International Inc 2016 COMPASS MODE ...
Страница 67: ...Doc 12 7852 r05 8 5 16 67 Aqua Lung International Inc 2016 REFERENCE ...
Страница 72: ...Doc 12 7852 r05 8 5 16 72 Aqua Lung International Inc 2016 TECHNICAL DATA ...
Страница 79: ...www aqualung com ...