![Aqua Lung i550C Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/aqua-lung/i550c/i550c_owners-manual_2958540056.webp)
Doc. 12-7909-r04 (10/31/18)
56
TECHNICAL DATA
© Aqua Lung International, Inc. (2018)
SPECIFICATIONS
CAN BE USED AS
• Dive Computer (Air or Nitrox)
• Digital Depth Gauge/Timer
DIVE COMPUTER PERFORMANCE
• Bühlmann ZHL-16C based Z+ algorithm
• Decompression in agreement with Bühlmann ZHL-16C
• No Decompression Deep Stops - Morroni, Bennett
• Decompression Deep Stops (not recommended) - Blatteau, Gerth, Gutvik
• Altitude - Buhlmann, IANTD, RDP (Cross)
• Altitude corrections and O2 limits based on NOAA tables
OPERATIONAL PERFORMANCE
Function:
Accuracy:
• Depth
±1% of full scale
• Timers
1 second per day
Dive Counter:
• DIVE/GAUGE displays Dives #1 to 24 (0 if no dive made yet)
• Resets to Dive #1, upon diving (after 24 hours with no dives)
Dive Log Mode:
• Stores 24 most recent DIVE/GAUGE dives in memory for viewing
• After 24 dives, adds 25th dive in memory and deletes the oldest dive
Altitude:
• Operational from sea level to 4,270 m (14,000 ft) elevation
• Measures ambient pressure every 30 minutes when inactive, upon activation, every 15 minutes while activated.
• Does not measure ambient pressure when Wet.
• Compensates for Altitudes above sea level beginning at 916 m (3,001 ft) elevation and every 305 m (1,000 ft)
higher.
Power:
• (1) 3 v, CR2450, Lithium battery (Panasonic or equivalent)
• Shelf life Up to 5 years (dependent on battery manufacturer)
• Replacement User (annual recommended)
• Use Life 100 dive hours if (1) 1 hour dives per dive day to 300 hours if (3) 1 hour dives per day
Battery Icon:
• Warning - icon on solid at 2.75 volts, Battery change recommended
• Alarm - icon on flashing at 2.50 volts, change the Battery
Activation:
• Manual - push button (recommended), required prior to dive if H2O ACT (activation) is set OFF.
• Automatic - by descent in water (if H2O ACT is set ON)
• Cannot be manually activated deeper than 1.2 M (4 FT), if H2O ACT is set OFF.
• Cannot operate at elevations higher than 4,270 m (14,000 ft)
Operating Temperature:
• Out of the water - between -6.6 and 60 °C (20 °F and 140 °F).
• In the water - between -2.2 and 35 °C (28 °F and 95 °F).
Содержание i550C
Страница 7: ...Doc 12 7909 r04 10 31 18 7 Aqua Lung International Inc 2018 GETTING STARTED...
Страница 12: ...Doc 12 7909 r04 10 31 18 12 Aqua Lung International Inc 2018 DIVE FEATURES...
Страница 17: ...Doc 12 7909 r04 10 31 18 17 Aqua Lung International Inc 2018 DIVE SURFACE MODE...
Страница 32: ...Doc 12 7909 r04 10 31 18 32 Aqua Lung International Inc 2018 DIVE OPERATION...
Страница 44: ...Doc 12 7909 r04 10 31 18 44 Aqua Lung International Inc 2018 GAUGE MODE...
Страница 48: ...Doc 12 7909 r04 10 31 18 48 Aqua Lung International Inc 2018 REFERENCE...
Страница 53: ...Doc 12 7909 r04 10 31 18 53 Aqua Lung International Inc 2018 TECHNICAL DATA...
Страница 59: ...www aqualung com...