Quick Install for your Aqua Logic Delta Star Heat Pump  

 

Unpack your Delta Star Heat Pump: 

 

Carefully remove the Heat Pump from the box by reaching underneath the Heat Pump 
and lifting it by its base.  NEVER lift the Heat Pump by its cover to avoid personal injury or 
damage to the Heat Pump (See illustration). 

 

Use a Phillips head screwdriver to remove the two screws on opposite ends of the cover.   

Place your Aqua Logic water Heat Pump: 

 

Place the water Heat Pump on a sturdy flat surface. 

 

Make sure that the unit is resting on its base to avoid damage.   

 

If you place the Heat Pump in a cabinet, allow at least ½” of space between the Heat 
Pump and the walls of the cabinet to avoid vibration and noise.   

 

Delta Star Plumbing: 

 

Your Aqua Logic flow-through Heat Pump requires an external water pump (not supplied) 
for proper operation. 

 

The Heat Pump should be the last piece of equipment in the plumbing before the water is 
returned to the tank or sump (after pump and filters).   

 

Use male-pipe-thread (MPT) fittings of the diameter below to connect your Heat Pump to 
your system.  Use the same or larger diameter pipe or hose for your plumbing for best 
water flow. 

 

We suggest installing unions and ball valves (not included) on the inlet and outlet of the 
Heat Pump for easier installation and removal of the Heat Pump from the system for 
maintenance or repair (if necessary). 

 

Be sure that the water flow through your Aqua Logic Heat Pump goes into the water inlet 
(bottom) and out the top to prevent potential damage (see illustration). 

 

If you use flexible hose to plumb your system or connect your Heat Pump, make sure 
that the hose is not kinked to prevent restricted flow and potential damage to your Heat 
Pump. 

 

Avoid elbows in your plumbing to minimize flow loss through your system. 

 

For most efficient operation, we recommend the minimum and maximum flow rates listed 
in the specifications sheet for each model. 

 

Do 

NOT

 operate the Heat Pump without adequate water flow. 

Electrical Hookup: 

 

We suggest using a dedicated power circuit for best operation and longest life of the Heat Pump. The circuit must be rated to handle the maximum 
load of the Heat Pump. 

 

We highly recommend that you use a ground-fault interrupter (GFI) to avoid electrical shock.  You can obtain an inline GFI from Aqua Logic, a local 
hardware store if the outlet in the wall does not have a GFI installed.   

 

Avoid using an extension cord on your Heat Pump.   

 

Temperature controller installation: 
 

o

 

Follow the instructions included with the controller to install it.  

o

 

Install the sensor for the controller “upstream” (ahead) of Heat Pump. 

o

 

Plug the Heat Pump into the controller. 

o

 

Plug the controller into the wall outlet. 

o

 

Program or adjust the controller to your desired temperature. (see Heat Pump Controller Programming) 

 

Your Aqua Logic Heat Pump is now installed and ready for operation! 
 

 
 
 
 
 
 
 
 

YES 

 

NO 

 

How to lift your Aqua Logic Heat Pump 

 
   

 

 

Condenser and Evaporator 

Water in and outlets

 

 

Содержание DSHP-10-WCMD

Страница 1: ...______ Installation and Maintenance Manual For Delta Star Water cooled Marine Duty In Line Water Heat Pumps Models DSHP 4 WCMD thru DSHP 10 WCMD DSHP 9 WCMD shown Use Quick Install page for easy setup...

Страница 2: ...mium quality components to assemble equipment that will operate faithfully for years You can call us or visit us on the web for technical assistance before and after the sale We are committed to makin...

Страница 3: ...or repair if necessary Be sure that the water flow through your Aqua Logic Heat Pump goes into the water inlet bottom and out the top to prevent potential damage see illustration If you use flexible h...

Страница 4: ...fittings for leaks Apply electrical power to the Heat Pump Adjust the controller to the desired water temperature See Operation and Programming Important Regulate condenser water until pressure on th...

Страница 5: ...ss either up key to increase or the down key to select the correct Stage 1 mode Stage 1 MUST be in the H1 mode for correct operation 5 Press the SET key again to access the chill mode set point temper...

Страница 6: ...a temperature controller on the lights to shut them off and to sound off an alarm if water temperature rises more than 5 F above the Heat Pump set point Keep a spare pump on hand in case your primary...

Страница 7: ...sure to wear appropriate protective gear Use extreme caution when using caustic chemicals around your system To remove accumulated organics slime Remove power from the Heat Pump Wear protective eyewea...

Страница 8: ...hes Weight lbs DSHP 4 WCMD 1 3 4050 115 7 2 R 134A 10 20 3 5 23 x 14 x 14 75 DSHP 5 WCMD 1 2 6000 115 9 5 R 134A 12 25 3 5 1 1 24 x 16 x 16 125 DSHP 6 WCMD 1 2 6000 230 4 8 R 134A 12 25 3 5 1 1 24 x 1...

Страница 9: ...ation or maintenance by user or their agent Damage caused due to misapplication of product Damage caused by corrosion abuse accident alteration or improper use Damage caused by flood fire earthquake t...

Отзывы: