![Aqua Laser SCS-266 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/aqua-laser/scs-266/scs-266_user-manual_2958464018.webp)
18
MAINTENANCE
1. When you have finished steam cleaning, ensure both of the power switches are turned
off and that the plug is removed from the wall.
2. Empty the remaining water from the water tank.
3. Microfiber steam mop pads can be machine washed at 60°C (140°F) maximum. For
heavily soiled pads soak in warm water with detergent or a mild stain remover. Allow
cloths to dry completely before storing.
NOTE: DO NOT USE FABRIC SOFTENER
BRUSHROLL MAINTENANCE
At least once a month, check for and remove excessive lint, string or hair from the revolving
brushroll. A little preventative maintenance will keep your AQUA LASER SPECIAL EDITION
looking new and will ensure continued cleaning effectiveness.
IMPORTANT:
Rotate screw ¼ turn until the indicator is aligned with the ‘ unlock’ symbol.
TROUBLE SHOOTING
Problem
Check
What to do
Unit has no power.
Appliance is not properly plugged
into an electrical outlet or is not
switched on.
The electrical socket is faulty.
Insert plug into an electrical outlet
and switch the steam cleaner on.
Check the socket by unplugging
the steam cleaner and plugging it
into a different electrical socket.
Very low or no steam is emitted
when the steam cleaner is on.
The tank is empty.
Fill the water tank with water.
Brushroll is not turning.
Large debris has clogged the
inlet.
Clean debris from inlet.