manualshive.com logo in svg
background image

Aqua-Hot™ Hydronic Heating System Owner’s Manual  07/04

1.1

Marking Plate

Marking

Plate

 

AHE-100

02S

12 VDC / 170 Watts

Model Number

Diesel-Burner / DC Power

Serial Number

       Electric Heating 

     Element / AC Power

Manufactured Date

Fuel Type / Firing Rate

02-637

120 VAC, 60 Hz / 1.65 kW

06-02

DIESEL / 50,000 BTU

R

          Testing 

        Engineers

      International

Listing No. 02L02

Complies with the requirements 

               of UL 307A

            Made in U.S.A.

    For Installation Only in Compartment Completely Closed Off from Living Quarters and Accessible

  

 

  Only from the Outdoors.

     Exhaust system MUST NOT terminate beneath the vehicle or under an openable window or vent.

                                           Combustion Air MUST BE supplied from outside the vehicle.

                               CAUTION:  This appliance operates on both AC and DC Electrical Power.

    The AC Powered Electrical Heating Element can be wired using flexible nonmetallic cable (ROMEX).

 

 

                                                             USE COPPER CONDUCTORS ONLY

 

  Use 25 Amp fuse for over current protection for DC Power Supply.

                           Use 20 Amp Circuit Breaker for over current protection for AC Power Supply.

                        Mount Heater near a Bay / Storage Door so Access Cover can be easily removed.

                  

                                 Minimum Heater clearances

 

                            Front (Decal Sides) - Open Access

 

 

         Back - 0 inches

 

 

           Top - 6 inches

 

 

                 

 

              Install in strict compliance with local codes, NFPA

 

                         501c and manufacturer’s instructions.

           For additional product installation information visit www.aqua-hot.com or call 1-800-685-4298

By Vehicle Systems, Inc.  Ft. Lupton, CO 80621

Manufactured 

   Date Box

Serial Number

         Box

Model Number

         Box

SECTION 1:  OVERVIEW

Figure 2

2.1  Activating the Aqua-Hot Heating System
Diesel-Burner

Turn the

 Diesel 

switch

ON

; reference

 Figure 3

. This procedure will

activate the Diesel-Burner and the indicator light located on the Diesel

switch.  Allow 10-20 minutes for the Aqua-Hot System to reach operating

temperature.  Please note that the Diesel-Burner is the 

primary heat

source

 for heating both the interior and the domestic hot water (such as

when cool ambient temperatures exist and/or when there is a high de-

mand for domestic hot water).

Electric Heating Element(s)

Low:

Turn the 

Electric

 switch 

ON

 in conjunction with the High / Low switch

placed in the 

LOW

 position; reference 

Figure 3

.  This procedure will

activate the 120 VAC / 1650 Watt Electric Heating Element and the 

indicator lights located on both the Electric and High / Low switches.

Allow 1-2 hours for the Aqua-Hot System to reach operating temperature.

High:

Turn the 

Electric

 switch 

ON

in conjunction with the High / Low switch

placed in the 

HIGH

 position; reference 

Figure 3

.  This procedure will

SECTION 2:  ACTIVATING THE AQUA-HOT’S HEAT SOURCES

Heat

Sources

Please read the complete Owner’s Manual prior to operating your Aqua-

Hot Heating System.  Also, be sure to fill out and mail in your Owner’s

Information Card located at the front of this manual.

NOTE: 

The “Diesel” switch can also be used to reset a 12 Volt-DC Low    

 

Voltage fault.  Please reference Section 6.

Page  2

Содержание AHE-120-04X

Страница 1: ...Aqua Hot Hydronic Heating System Owner s Manual 07 04 OWNER S MANUAL Model Number AHE 120 04X 12 VDC...

Страница 2: ...l Address Motorhome Model Date of Purchase Motorhome Aqua Hot Model No reference Figure 1 Marking Plate Aqua Hot Serial No reference Figure 1 Marking Plate Vehicle Systems Warranty Department 15549 Ea...

Страница 3: ...em 4 3 4 Diesel Burner Component Overview 5 3 5 Diesel Burner Operational Flow Chart 5 3 6 Precautions 6 Section 4 Maintenance 4 1 Maintenance Schedule 7 Section 5 Winterization 5 1 Domestic Hot Water...

Страница 4: ...FDA For additional information regarding this GRAS antifreeze product please contact the Technical Support Department at 1 800 685 4298 or visit the website at www vehiclesys com SECTION 1 OVERVIEW Aq...

Страница 5: ...1 800 685 4298 By Vehicle Systems Inc Ft Lupton CO 80621 Manufactured Date Box Serial Number Box Model Number Box SECTION 1 OVERVIEW Figure 2 2 1 Activating the Aqua Hot Heating System Diesel Burner T...

Страница 6: ...rner and the Electric Heating Element s are thermostatically controlled Either or both heating sources will automatically maintain the temperature fo the Aqua Hot s water and antifreeze solution betwe...

Страница 7: ...procedure will activate the Engine Preheat Circulation Pump and circulate the engine s coolant through the Engine Preheat System This feature will adequately warm the engine for easy start ups on coo...

Страница 8: ...lling for heat will the Motor 2 begin to operate Operation sequence once the Aqua Hot s Diesel switch is turned ON NOTE The Diesel switch s Indicator Light will illuminate reference Figure 3 while the...

Страница 9: ...esel Burner will automatically turn back ON once the coolant temperature reaches the preset temperature of approximately 160 5 degrees Fahrenheit The Motor 2 will continue to run for approximately thr...

Страница 10: ...plenishing fill the Aqua Hot s Expansion Tank to the FULL HOT level mark Be sure to use a 50 50 mixture of water and P G antifreeze Annually WARNING Before cleaning or servicing disconnect all power s...

Страница 11: ...quate piece of hose onto the suction side of the domestic water demand pump D Place the opposite end of the hose into an adequate supply of FDA approved RV Antifreeze E Open close all interior and ext...

Страница 12: ...te by unscrewing the four cover screws C Remove the Aqua Hot s Access Cover and check for loose plug connec tors on the Diesel Burner s Control Unit located on the under side reference Figure 1 D Chec...

Страница 13: ...each particular zone is calling for heat The GREEN indicator lights also indicate that VDC power is being supplied to the particular interior heating zone s Heat Exchangers i e fan motors If any of th...

Страница 14: ...ng supplied to the Aqua Hot s Boiler Tank NOTE The Aqua Hot s VDC VAC Control Thermostat will automatically activate the Diesel Burner and or the Electric Heating Element s only if the Diesel and or E...

Страница 15: ...the Heater by the end user This warranty does not apply to damage or failure of the AQUA HOT Heater or the vehicle into which it was installed due to improper installation assembly maintenance abuse...

Страница 16: ...Aqua Hot Hydronic Heating System Owner s Manual 07 04 Date Service Performed Service Center OWNER S SERVICE LOG Date Service Performed Service Center OWNER S SERVICE LOG Continued...

Страница 17: ...Aqua Hot Hydronic Heating System Owner s Manual 07 04 MEMO...

Страница 18: ...s Manual 07 04 Aqua Hot Motor Coach Heating System Owner s Manual 08 03 15549 East Highway 52 Fort Lupton Colorado 80621 1 800 685 4298 Fax 303 857 9000 Copyright 2003 Vehicle Systems Inc All rights r...

Отзывы: