Aqua-Hot™ Motor Coach Heating System Owner's Manual 05/02

Aqua-Hot™ Motor Coach Heating System Owner's Manual 05/02

Page 2-2

SECTION 2:  OPERATING INSTRUCTIONS

2.2 Zone Thermostat(s) Operation
Interior Room Thermostats

Simply adjust each Room Thermostat to the desired temperature.  Then

whenever a Room Thermostat “calls-for-heat” the Aqua-Hot’s Circulation
Pump(s) and Interior Zone Fans will be activated.  These devices together
will supply warmth and comfort to each interior heating zone.  Please
contact your specific motorhome manufacturer for the exact Room
Thermostat location(s).

Bay Thermostat

Simply adjust the Bay Thermostat to approximately 40 degrees
Fahrenheit.  This will prevent freezing of the domestic water storage
system.  Please contact your specific motorhome manufacturer for the
exact Bay Thermostat location.

Comfort
Control

Heat
Source,
continued

NOTE:  Both the Diesel-Burner and the 120 VAC Electric Heating Element
are thermostatically controlled.  Either, or both, heating sources will
automatically maintain the temperature of the Aqua-Hot's water and
antifreeze solution between approximately 175-200 degrees Fahrenheit.
So simply choose how you want to heat your coach/hot water and just
leave the Switch(s) (Diesel, Electric, or both) ON.

Page 2-3

SECTION 2:  OPERATING INSTRUCTIONS

Hot Water

2.3 Using the Domestic Hot Water System
When the Aqua-Hot is at operating temperature, the domestic water is
automatically heated as it is being used.  Because the Aqua-Hot does not
store any hot water simply open any hot water faucet and a continuous
supply of domestic hot water will be present within a few seconds.  This hot
water feature is continuous and is accomplished by the Aqua-Hot’s Mixer
Valve and Intergal Domestic Hot Water Heating System.  Please note that
the Diesel-Burner Control Switch must be ON to get an unlimited supply of
hot water (i.e. during showers).

Engine
Preheat

2.4 Using the Engine Preheat System

When the Aqua-Hot is at operating temperature, and the Diesel-Burner
and/or the 120 VAC Electric Heating Element Switch(s) is ON, follow
these simple instructions:
A.  Turn the Aqua-Hot's Engine Preheat Switch ON.  This procedure will
activate the Engine Preheat Circulation Pump.  Circulating the engine's
coolant through the Engine Preheat System will adequately warm the
engine for easy start-ups on cool mornings.  Please contact your specific
motorhome manufacturer for the exact Engine Preheat Switch location.

NOTE:  Allow approximately 1 to 2 hours of engine preheating run time.
Time will be shortest when the Diesel-Burner Control Switch is ON.

Содержание AHE-100-02S-12 VDC

Страница 1: ...Aqua Hot Motor Coach Heating System Owner s Manual 05 02 Owner s Manual Model Numbers AHE 100 02S 12 VDC AHE 200 02S 24 VDC...

Страница 2: ...To CUT HERE AND MAIL IN OWNER S INFORMATION Owner s Name Address City State Zip Code Telephone Coach Model Coach Date of Purchase Aqua Hot Model No Aqua Hot Serial No Vehicle Systems Warranty Departm...

Страница 3: ...emperature of the Aqua Hot s solution of water and antifreeze In addition the Aqua Hot has been designed to preheat the vehicle s engine prior to starting This feature provides easy engine start up wh...

Страница 4: ...tor light located on or near the Switch Please contact your specific motorhome manufacturer for the exact Diesel Burner Control Switch location Allow 10 20 minutes for the Sys tem to reach operating t...

Страница 5: ...hot water and just leave the Switch s Diesel Electric or both ON Page 2 3 SECTION 2 OPERATING INSTRUCTIONS Hot Water 2 3 Using the Domestic Hot Water System When the Aqua Hot is at operating temperat...

Страница 6: ...matically pass through the Engine Preheat Motoraide System transferring heat into the Aqua Hot s Heat Tank This design feature reduces the total operating hours of the Diesel Burner and the 120 VAC El...

Страница 7: ...Operational Flow Chart Page 2 6 NOTE When the Aqua Hot s Diesel Burner is switched OFF by the CONTROL THERMOSTAT A The MOTOR 2 will shut off once the three 3 minute Purge Cycle has expired The MOTOR...

Страница 8: ...tion of water and antifreeze to ensure that it is at the proper level Do this by visually checking the coolant level in the Aqua Hot s Expansion Tank see Figure 1 This should be checked only when the...

Страница 9: ...se onto the suction side of the domestic water demand pump D Place the opposite end of the hose into an adequate supply of FDA approved RV Antifreeze approximately 2 gallons will be required Page 4 1...

Страница 10: ...re and in place on the underside of the Control Unit Check House Batteries and Charging System 120 VAC Electric Heating Element does not produce heat or hot water when motorhome is plugged into shore...

Страница 11: ...A HOT Heater or the vehicle into which it was installed due to improper installation assembly maintenance abuse neglect accident or the use of parts not supplied by Vehicle Systems Inc Vehicle Systems...

Страница 12: ...ing System Owner s Manual 05 02 Aqua Hot Motor Coach Heating System Owner s Manual 05 02 OWNER S SERVICE LOG OWNER S SERVICE LOG Continued Date Scheduled Service Service Center Continued Date Schedule...

Страница 13: ...Specialists Motor Coach Heating Specialists Motor Coach Heating Specialists Manufacturers and Distributors Manufacturers and Distributors Manufacturers and Distributors Manufacturers and Distributors...

Отзывы: