In order to ensure maximum performance and longev-
ity of an Aqua-Hot heating system’s boiler tank and
associated components, it has been determined that
there is a need to use distilled, de-ionized, or soft water
in combination with concentrated propylene glycol for
the Aqua-Hot’s antifreeze and water heating solution.
Please note that this is only necessary when mixing
concentrated propylene glycol antifreeze with water;
suppliers of pre-mixed antifreeze are responsible for
the use of high-quality (distilled, de-ionized, or soft)
water when preparing their antifreeze for sale.
Hard water possesses a high-level of calcium and
magnesium ions, which deplete the propylene glycol
antifreeze’s corrosion inhibitors. This, in turn, causes
the antifreeze and water heating solution to begin turn-
ing acidic, which can corrode the Aqua-Hot’s Boiler
tank and associated components prematurely. There-
fore, concentrated propylene glycol should be diluted
with distilled, de-ionized, or soft water which is 80 ppm
or less in total hardness. The local water agency should
have up-to-date water quality reports which should
indicate if the local tap water is within this guideline.
appendix D: antifreeze Mixture Water Quality Recommendations
Содержание 375D
Страница 1: ...2008 Aqua Hot Heating Systems Inc Installation Manual...
Страница 38: ...Wiring Diagram Appendix A...
Страница 39: ...2008 Aqua Hot 375 D Hydronic Heating System Installation Manual Rev A A 1 Appendix A Wiring Diagram...
Страница 40: ...Wire Gauge Information Appendix B...
Страница 42: ...Antifreeze Types Appendix C...
Страница 44: ...Antifreeze Mixture Water Quality Recommendations Appendix D...
Страница 46: ...Antifreeze Terms and Mixture Ratio Appendix E...
Страница 49: ...15549 East Highway 52 Fort Lupton Colorado 80621 1 800 685 4298 Fax 303 857 9000 www aqua hot com...