Aqua Guard DualFlo DF102STL Скачать руководство пользователя страница 1

1

aquaguardpoolsystems.com

DualFlo

2-Speed Pump

Owner’s Manual

Installation, Operation 

and Service

Models:  DF102S, DF102STL 

DF152S, DF152STL

Notice to Installer 

This manual contains important information about the installation, operation and safe use of 

this product. Once installation is complete, this manual must be given to the owner/ operator 

of this equipment. 

This equipment must be installed and serviced by a qualified technician in accordance with all applicable 

codes and ordinances. Improper installation can create hazards which could result in property damage, 

serious injury or death. Improper installation will void the warranty. 

The NOTICE label indicates special instructions that are important but not related to hazards.

WARNING

Содержание DualFlo DF102STL

Страница 1: ...installation is complete this manual must be given to the owner operator of this equipment This equipment must be installed and serviced by a qualified technician in accordance with all applicable cod...

Страница 2: ...Failure to follow safety and operation instructions could result in violent separation of the pump housing cover or filter housing due to pressure in the system which could cause injury or death Suct...

Страница 3: ...e wire size is sufficient for pump HP and distance from power source Wiring should be done in accordance with applicable codes by a competent electrician We recommend the installation of a ground faul...

Страница 4: ...trainer bodies and locater above water close suction line valve and fill pump with water in order to prime For pumps with strainer bodies and located above water prime by removing strainer cover and f...

Страница 5: ...e is 7 2 7 4 Pump Maintenance 1 Motors are self lubricating no lubrication required 2 Clean hair lint strainer if you have a strainer body pump 3 Visually inspect motor for blockage of air vents on mo...

Страница 6: ...RE 1 Discharge valve or inlet fittings closed too much 2 Return lines too small 3 Dirty filters NOISY PUMP AND MOTOR 1 Plugged basket in skimmer or hair in lint strainer 2 Worn motor bearings 3 Valve...

Страница 7: ...52871 Impeller for DF102S and DF102STL 1 7b AGX272971 Impeller for DF152S and DF152STL 1 8 AGX280030 Seal Assembly 1 9 AGX252701 Pump Housing 1 10 AGX310400 Housing O Ring 1 11 AGX120160 Screw ST 5 5...

Страница 8: ...ou specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise s...

Отзывы: