Octopus Microprocessor Controller Protocol:
As discussed in the above steps there are a few steps you will want to take before starting your
Octopus Reverse Osmosis Unit. Discussed below are the steps the microprocessor
will take after
you have started to filter water. Allow for the system to pressurize, check for any leaks. After 10
seconds of the feed being turned on, plug the AC plug (power chord) into your 110v outlet. The
controller will be behaving as described below after the power is connected.
You will want to
begin restricting the “T‟ flow restrictor after the initial Membrane flush to achieve your 80 psi, or
1:1 waste water ratio. (Whichever happens first!)
1) a) Power on Unit will countdown for 10 seconds and make
sure the feed
pressure is
present
.
b) If Source Light flashes
This is an indication that the feed pressure
is either
too low or not present, Check that water supply is turned on.
c) When the Source Light is on
This tells us that the feed pressure is ok, and
now the unit will automatically flush itself for 30 seconds.
(This countdown is constantly monitored, such that if pressure is lost the Auto Flush will
stop) This is where you will
begin to restrict
the „T‟ flow restrictor.
SEE STEP 7
ON
SYSTEM INSTALLATION.
2)
a) Auto flush finishes “Aqua EE” Controller will check both „Low‟ and „High‟
pressure switches to assure pump can run safely.
b) Again if feed pressure is lost
the Source Light will flash
.
c) If pressure is ok the Octopus will begin
will produce clean water automatically.
3) When product line is full (via float valve or external shut off valve) the Unit will
light up
the “Full‟ light and begin to flush the R
O membrane again.
4) TDS Reading - The Octopus controller will display the water quality in parts per million
(ppm) in a 099ppm range. If the TDS exceeds 99ppm, the display will flash 099P.
5) The “
Octopus
” controller will
close the
incoming solenoid until the High Pressure switch
has been activated for 10 or more seconds. This is to eliminate any false triggering of
the shut off.
If at any time the feed pressure is cut, than the unit will blink the source light until positive feed pressure is
reapplied.