AQUA FORTE SC997 Скачать руководство пользователя страница 1

Mini Heat Pump for Swimming Pool

User and Service Manual

Содержание SC997

Страница 1: ...Mini Heat Pump for Swimming Pool User and Service Manual...

Страница 2: ......

Страница 3: ...on Instructions 7 IV Running Test 9 1 Inspection Before Running Test 9 2 Control Function Description 10 2 1 The buttons of LED wire controller 10 2 2 Controller display instructions 10 2 3 Definition...

Страница 4: ...ith grounding sockets Independent switch must be offered with the unit 3 The following safety factors need to be considered Please read the following warnings before installation Be sure to check the...

Страница 5: ...per installation may result in fire electric shock falling of the unit or water leaking Use professional tools for doing electrical work If power supply capacity is insufficient or circuit is not comp...

Страница 6: ...a problem or an fault code Please turn off power and stop running the unit Otherwise it may cause electric shock or fire Be careful when the unit is not packed or not installed Pay attention to sharp...

Страница 7: ...General Info Max Power Input kW 0 9 1 5 Max Current A 4 1 7 1 Advised Pool Size m 5 15 10 25 Controller LED Controller Power Supply 220 240V 50Hz Water Temp Heating Mode 10 40 Running Ambient Temp 5 4...

Страница 8: ...5 2 Unit Dimensions Unit mm Model SC997 Unit mm Model SC998...

Страница 9: ...m tube heat exchanger 16 Back net 3 Fan blade 10 Pipe assembly 17 Top cover 4 Fan motor 11 Power supply waterproof connector 18 Top cover 5 Motor support 12 Water flow switch 19 Pillar 6 Chassis 13 Ri...

Страница 10: ...future 2 It must be installed and fixed on flat concrete floor The floor is stable to support the weight of the unit 3 A water drainage device must be provided close to the unit in order to protect th...

Страница 11: ...front of heat pump Leave at least 500mm of empty space around the sides and rear of heat pump Do not put any stuff on or in front of heat pump 3 Installation Layout The installation diagram is for ref...

Страница 12: ...onfirm below items and write in block Correct unit installation Power supply voltage is the same as unit rated voltage Correct piping and wiring Air inlet outlet port of unit is unblocked Drainage and...

Страница 13: ...for 5 seconds to check the parameters Press and to turn the pages to check different parameters Press M key under the parameter checking status to enter the enter the status of parameters setting Pres...

Страница 14: ...justable J Power off protection 0 1 1 Yes Adjustable O Ambient temperature of antifreeze protection 0 15 5 41 Adjustable P Coil temperature of entering defrosting 19 0 3 27 Adjustable U Coil temperatu...

Страница 15: ...ion system regularly to avoid the damage of the unit because of a dirty or clogged filter Discharge the water from the bottom of the water pump if the heat pump will stop running for a long time speci...

Страница 16: ...106 10018 380...