6
Model
SC974
SC975
SC976
SC977
SC978
SC979
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity (kW)
6.8
9.0
12.6
16.1
20.0
24.0
COP Range
13.5~6.3
14~6.5
14~6.4
15~6.5
15~6.5
14.5~6.4
Average COP at 50% Speed
9.2
9.0
9.5
9.6
9.3
9.6
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity (kW)
5.0
6.5
9.0
11.0
14.0
16.2
COP Range
6.8~4.3
6.8~4.5
7~4.4
7~4.5
7~4.6
7.2~4.5
Average COP at 50% Speed
6.1
6.2
6.3
6.3
6.2
6.3
TECHNICAL SPECIFICATIONS
Advised pool volume (m
3
) *
15~30
20~50
30~60
40~75
50~90
60~110
Operating air temperature (
°C
)
-5
°C
~43
°C
Power supply
230V 1Ph
Rated input power (kW)
0.18~1.17
0.24~1.45 0.32~2.10
0.39~2.5
0.5~3.1
0.56~3.7
Rated input current (A)
0.79~5.1
1.05~6.4
1.4~9.0
1.7~10.7
2.18~13.3 2.45~16.1
Sound level at 10m dB (A)
18.5~28.0
19~28.4
22.2~30.8 21.2~34.4
23.4~34.1
21.8~36
Advised water flux (m³/h)
2~4
2~4
4~6
6~8
7~10
10~12
Water connection (mm)
50
Remarks:
This heat pump is able to perform normal within air temp -5°C
~
+43°C, efficiency will not be guaranteed
out of this range. Please take into consideration that the pool heat pump performance and parameters
are different under various conditions.
Related parameters are subject to adjustment periodically for technical improvement without further
notice. For details please refer to nameplate.
7.
Dimension
Содержание INVERSMART
Страница 1: ...INVERSMART INVERTER ZWEMBAD WARMTEPOMP Handleiding...
Страница 29: ...INVERSMART INVERTER SCHWIMMBADW RMEPUMPE BENUTZERHANDBUCH...
Страница 50: ...20...
Страница 59: ...INVERSMART INVERTER Pompe chaleur Inverter pour piscine Le manuel de fonctionnement...
Страница 89: ...INVERSMART INVERTER POOL HEAT PUMP MANUAL...
Страница 115: ...25 Please set family name and choose location of device Create Family b Register through third party application...