2. 

Product Description

®

Aquafilter  EXCITO

 is a modern filtration system designed for the purification of potable and general-use water. Equipped with four in-line 

cartridges, the system effectively removes: rust, sand and sediments (cartridges: 

AIPRO-20MS

 and 

AIPRO-1MS

); organic contaminants 

and chlorine (cartridge 

AICRO-L3

); heavy metals such as lead, arsenic, cadmium as well as iron contents (

AICRO-L4

).

1. 

Safety Precautions

Product  may  be  installed  only  by  trained  service  professionals.  Only  original  replacement  parts,  filter  cartridges  and 
accessories made by manufacturer may be used.
 

Compliance with the following instructions ensures:
- problem-free product operation,
- manufacturer's warranty.

Failure to comply with the following instructions will result in loss of warranty. 

1) The system is designed for the filtration of potable water only.
2) Remember to remove safety clip before removing flexible tubing and elbow.

®

Only original 

Aquafilter

 replacement cartridges may be used. Using cartridges made by other manufacturers results in a loss of warranty 

and relieves the manufacturer of responsibility for the incorrect operation of system.

EN

Inlet water temperature..........

...................................................................................................................................

between 2°C and 

23

°C

Water supply pressure

.........................................................................................................................................................................

 

6

 bar

Water supply adapter

.............................................................................................................................................................................1/2”

Outlet tubing

..........................................................................................................................................................................................1/4”

Dimensions (height x width x depth).................................................................................................................390 mm x 355 mm x 100 mm

3. 

Technical Specifications

Flexible tubing

KTPE14W*

Shut-off valve 

SEWBV1414*

Water filtration System 

EXCITO

Chrome-plated adapter 

FT02

(3/4" MIP x 3/4" FIP)

brak w zestawie - dodatkowe wyposa¿enie.

Chrome-plated adapter 

FT07

(3/4" MIP x 3/4" FIP x 1/4" FIP)

Teflon tape

TAS0004*

Chrome-plated adapter

FT06*

(1/2” MIP x 1/2” FIP x 1/4” FIP) 

4. 

Included in the Box

Installation manual

XI-EXCITO

WARNING! The system should not be used with biologically contaminated water or water of unknown origin.  

IMPORTANT  NOTE! 

The  system  must  be  secured  from  high  pressures  and  rapid  pressure  changes  caused  by  local  water  supply 

systems. Pressure regulator must be installed on the inlet of the system's water supply. The system's optimal performance pressure is 3.5 
bar - pressure regulator must also be set to this parameter. Failure to install pressure regulator will result in loss of warranty. Regulator may 
be purchased separately - catalog nr. 

ADV-REG_K

-CR

.

ADV-REG

_K

Installation Manual 

Èíòñðóêöèÿ ìîíòàæà

 

Instrukcja monta¿u 

www.aquafilter.com

* Components are placed inside of filter housing.

Pressure regulator 

ADV-REG _K

ADV-REG

-CR

_K

(not included in the set) 

Chrome

plated

Faucet 

FXFCH17-C

Содержание EXCITO

Страница 1: ...www aquafilter com Installation Manual...

Страница 2: ...system EN Inlet water temperature between 2 C and 23 C Water supply pressure 6 bar Water supply adapter 1 2 Outlet tubing 1 4 Dimensions height x width x depth 390 mm x 355 mm x 100 mm 3 Technical Spe...

Страница 3: ...g Flexible Tubing 1 Insert flexible tubing 1 5 cm 0 6 in deep into the quick connector Fig 4 2 Insert safety clip Fig 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 6 1 Removing and Installing the Elbow in Quick Con...

Страница 4: ...removing unscrewing the element may result in inadequate connection and water leak fig 6 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 7 System Installation Stage I IMPORTANT NOTE Manufacturer is not responsibl...

Страница 5: ...TANT NOTE Manufacturer is not responsible for any damages that result from improper installation or use of system System installation should be performed only in temperatures above 2 C 35 6 F IMPORTAN...

Страница 6: ...push the tubing all the way into the valve and tighten the nut 9 Connect flexible tubing of SEWBV1414 valve with system s water inlet IN red ring Screw chrome plated adapter FT02 onto the hot water p...

Страница 7: ...flexible tubing supplying water and connecting faucet with the system put the tubing 11 through the metal nut 10 and plastic tightening ring 9 put the insert 8 into the tubing push flexible tubing all...

Страница 8: ...PPLY INLET WATER SUPPLY INLET AIPRO 20MS AIPRO 3 L AICRO L3 AICRO L4 AIPRO 20MS AIPRO 3 L AICRO L4 TLCHF FP 9 1 Cartridge Connection Scheme set EXCITO CLR CRT 9 2 Cartridge Connection Scheme set EXCIT...

Страница 9: ...rade activated coconut carbon It is designed to remove up to 99 of chlorine sediments and organic contaminants In addition a special filtration media removes heavy metals such as lead nickel chromium...

Страница 10: ...ble tubing from the system inlet outlet 2 4 Remove the elbows one from the water inlet of the first cartridge one from the water outlet of the last cartridge IMPORTANT NOTE While removing the elbows b...

Страница 11: ...cartridges with regular connectors Disconnect tubing from elbow inlet connector attached to cartridgeAIPRO 20MS Disconnect tubing from elbow outlet connector attached to cartridge AICRO L4 Proceed as...

Страница 12: ...rew in connectors into new filter cartridge NOTE During installing screwing in individual connectors do NOT withdraw unscrew them at any time This may result in connection damage and future water leak...

Страница 13: ...correctly inserted tubing is mounted 1 5 cm deep inside elbow connector 3 Secure the connection with safety clip NOTE When pulling out the tubing use caution to prevent the tubing from damage Collapsi...

Страница 14: ...in an open position slowly open water supply valve 7 IMPORTANT NOTE Before the first use and after each cartridge replacement procedure the system should be flushed with 15 liters of water Next allow...

Отзывы: