11
4. When the filter pump is turned off, the unit should also turn off automatically, if not, then adjust the flow switch.
Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take
several days to heat the water to the desired temperature. A good swimming pool cover can dramatically reduce
the required length of time.
Water Flow Switch:
It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate. It will turn on
when the pool pump runs and shut it off when the pump shuts off. If the pool water level is higher than 1 m above
or below the heat pump’s automatic adjustment knob, your dealer may need to adjust its initialstart-up.
Time delay -
The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive
contact wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will
trigger this time delay and prevent the unit from restarting immediately. Additional power interruptions during this
delay period do not affect the 3-minute duration of the delay.
3.9 Condensation
The air drawn into the heat pump is cooled by the operation of the heat pump to heat the pool water, which may
cause condensation on the fins of the evaporator. The amount of condensation may be as much as several litres per
hour at high relative humidity. This is sometimes mistakenly regarded as a water leak.
3.10 Operating modes for optimal use
POWER: Used primarily at the beginning of the season because this mode allows for very rapid temperature rise.
SMART: The heat pump has completed its primary task, in this mode; the heat pump is in a position to maintain the
pool water in an energy efficient manner. By automatically adjusting speed of compressor and fan the heat pump
delivers a higher efficiency.
SILENT: In the summer months when the heat output is minimal required, the heat pump in this mode is even more
economic. Added benefit; when the heat pump heats. It does so with minimal noise.
Содержание Inverboost Premium 10kW
Страница 1: ...Swimming Pool Heat Pump User and Service Manual ...
Страница 2: ......
Страница 7: ...5 2 Dimension mm Model UX11Csi32 UX14Csi32 ...
Страница 8: ...6 Model UX17Csi32 UX21Csi32 ...
Страница 9: ...7 Model UX30Csi32T UX35Csi32T ...
Страница 16: ...12 Dry contact timer connection Timer Dry contact pump connection ...
Страница 17: ...13 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM UX11Csi32 UX14Csi32 UX17Csi32 UX21Csi32 ...
Страница 31: ...27 8 Exploded Diagram Model UX11Csi32 UX14Csi32 ...
Страница 33: ...29 Model UX17Csi32 UX21Csi32 ...
Страница 36: ...32 Model UX30Csi32T UX35Csi32T ...
Страница 40: ...33 ...
Страница 42: ...35 4 Parameter checking and setting Click Parameter then enter the password 0757 ...
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ...A0201UX01 ...