Portable filtration units
16
To use the pulse cleaning system, follow the steps listed below in order to ensure the unit will
perform adequately.
1.
Connect the compressed air line to the unit with a 1/4" NPT connection. Tank should take
about 4 to 6 seconds to fill.
2 .
For a longer use of the cartridge, it is best to feed 60 PSI into the air tank. Max PSI is 90.
3.
Press the the red palm button to release the compressed air from the tank and to clean the
cartridge. (Figure 3a et 3b)
13 REPLACEMENT/CLEANING OF MAXIROLL / MAXICART FILTERS
WARNING!
Wear appropriate safety gear such as safety goggles or gloves
when replacing the cartridge. The filter cartridge may be
heavier than expected.
Do not shake or drop the cartridge.
Use
necessary precaution when replacing the filters to avoid injuries.
Frequency of pulse cleaning will depend on how often the unit is used or the type of dust to be
filtered. Decrease in suction is a sign to pulse clean the cartridge.
Figure 3a
Figure 3b
Figure 3a
Maxiroll
MAXIROLL
RED BOTTON
Figure 3b Maxicart
MAXICART
RED BOTTON