AQC MAXAIR Скачать руководство пользователя страница 5

Fume Arms

5

  4  MODEL NUMBERS

  4.1  Hanging or table / bench mount

  4.2  Telescopic fume arm

Models

Arm diameter

 

in / mm

Arm min. 

 

length

 

in / mm

Arm max. 

 

length

 

in / mm

 Standard 

hood 

 

diameter 

 

in / mm

Optional 

hood 

 

diameter

in / mm

Weight

lbs / kg

FA-TPGG4-06

4 / 102

52 / 1321

72 / 1829

8 / 203

-

19 / 8,6

FA-TPGG5-06

5 / 127

52 / 1321

72 / 1829

10 / 254

15 / 381

30 / 13.6

FA-TPGG6-06

6 / 152

52 / 1321

72 / 1829

13 / 330

20 / 508

36 / 16.3

Hanging

Bench 

mount

Stainless 

steel 

 

hanging

Stainless 

steel 

bench 

mount

Arm 

 

diameter

 

in / mm

Arm length

 

ft / m 

 Standard 

hood 

 

diameter 

 

in / mm

Optional 

hood 

 

diameter

in / mm

Weight

lbs / kg

FA-HPG3-03

FA-PPG3-03

FA-HSS3-03

FA-PSS3-03

3 / 76

3 / 1.0

7 / 178

14 / 6.4

FA-HPG3-05

FA-PPG3-05

FA-HSS3-05

FA-PSS3-03

3 / 76

5 / 1.5

7 / 178

16 / 7.3

FA-HPG4-05

FA-PPG4-05

FA-HSS4-05

FA-PSS4-05

4 / 102

5 / 1.5

8 / 203

17 / 7.7

FA-HPG4-07

FA-PPG4-07

FA-HSS4-07

FA-PSS4-07

4 / 102

7 / 2.1

8 / 203

19 / 8.6

FA-HPG4-08

FA-PPG4-08

FA-HSS4-08

FA-PSS4-08

4 / 102

8.5 / 2.4

8 / 203

22 / 10

FA-HPG5-07

FA-PPG5-07

FA-HSS5-07

FA-PSS5-07

5 / 127

7 / 2.1

10 / 254

15 / 381

38 / 17.2

FA-HPG5-10

FA-PPG5-10

FA-HSS5-10

FA-PSS5-10

5 / 127

10 / 3.0

10 / 254

15 / 381

43 / 19.5

FA-HPG5-14

FA-PPG5-14

FA-HSS5-14

FA-PSS5-14

5 / 127

14 / 4.3

10 / 254

15 / 381

47 / 21.3

FA-HPG6-07

FA-PPG6-07

FA-HSS6-07

FA-PSS6-07

6 / 152

7 / 2.1

13 / 330

20 / 508

44 / 20

FA-HPG6-10

FA-PPG6-10

FA-HSS6-10

FA-PSS6-10

6 / 152

10 / 3.0

13 / 330

20 / 508

52 / 23.6

FA-HPG6-14

FA-PPG6-14

FA-HSS6-14

FA-PSS6-14

6 / 152

14 / 4.3

13 / 330

20 / 508

60 / 27.2

FA-HPG8-07

FA-PPG8-07

FA-HSS8-07

FA-PSS8-07

8 / 203

7 / 2.1

13 / 330

20 / 508

57 / 25.9

FA-HPG8-10

FA-PPG8-10

FA-HSS8-10

FA-PSS8-10

8 / 203

10 / 3.0

13 / 330

20 / 508

66 / 29.9

FA-HPG8-14

FA-PPG8-14

FA-HSS8-14

FA-PSS8-14

8 / 203

14 / 4.3

13 / 330

20 / 508

74 / 33.6

Содержание MAXAIR

Страница 1: ...tion use and maintenance This manual is property of the owner Leave with the unit when set up and start up are complete AQC Dust Collecting Systems inc reserves the right to change design and specific...

Страница 2: ...racket installation hanging type no exhaust fan 11 8 4 Arm and ceiling bracket installation hanging type 13 8 5 Arm and bracket installation hanging type with exhaust fan 14 9 Optional equipment 15 9...

Страница 3: ...nnel using the system should be trained on safety measures and maintenance instructions 2 INFORMATION ON THE MAXAIR FUME ARM Model Serial number Delivery date Date of installation Name of customer Add...

Страница 4: ...include a direct drive fan extension swing boom for additional reach sliding rail with trolley etc 3 1 Each MAXAIR unit includes External and adjustable joints Painted steel or stainless steel tubes...

Страница 5: ...05 FA PPG4 05 FA HSS4 05 FA PSS4 05 4 102 5 1 5 8 203 17 7 7 FA HPG4 07 FA PPG4 07 FA HSS4 07 FA PSS4 07 4 102 7 2 1 8 203 19 8 6 FA HPG4 08 FA PPG4 08 FA HSS4 08 FA PSS4 08 4 102 8 5 2 4 8 203 22 10...

Страница 6: ...SE During normal operation the MAXAIR fume arm is pulled or pushed into position near the source of pollutants 8 to 16 from the source The hood tube grab handle on 5 6 and 8 arms only may be used for...

Страница 7: ...ersion 1 Socket set assembly 2 Flexible hose typ of 3 3 Socket tube 4 Hood tube 5 Damper handle 6 Connectors for hood movement typ of 4 7 Joint wheel 8 Capture hood 9 Hood grab handle 10 Articulating...

Страница 8: ...portable version 1 Socket set assembly 2 Flexible hose typ of 3 3 Socket tube 4 Hood tube 5 Damper handle 6 Connectors for hood movement typ of 4 7 Joint wheel 8 Capture hood 9 Hood grab handle 10 Art...

Страница 9: ...ble hose typ of 2 3 Socket tube fixed 4 Hood tube sliding twist and lock 5 Damper handle 6 Connectors for hood movement typ of 4 7 Joint wheel 8 Hood grab handle 9 Articulating joints typ of 4 10 Tele...

Страница 10: ...d with shipment Inspect box or crate appearance when receiving the goods Report damages to carrier immediately Failure to do so will void future claims Note Because of sizes and dimensions optional ov...

Страница 11: ...step 4 is completed 1 Install bracket on support structure at proper height for arm length Fasteners to support structure are not supplied Arm bracket can also be welded to structure if allowed or pe...

Страница 12: ...ds it s position and does not sag Proceed with left and right middle joints End with all four 4 adjustable joints at hood section 7 Move arm UP DOWN LEFT RIGHT to ensure arm stays in position 8 Procee...

Страница 13: ...nging type installation procedures 8 5 Arm and bracket installation hanging type with exhaust fan Note This type of installation will not require the duct flange The installation crew must ensure the...

Страница 14: ...exhaust air Place fan onto arm support bracket Align fan inlet flange bolt holes to bolt pattern on arm bracket Secure fan temporarily to support bracket using C clamps Proceed with steps 3 to 7 in a...

Страница 15: ...not force arm down at socket past the maximum bend This may cause damages in the spring and cable assembly in socket 9 1 1 Mounting The capture arm can be mounted on a wall Ensure the wall is level a...

Страница 16: ...l be required if bracket and arm are not of same diameters ex 1 hp 6 fan inlet with 5 diameter fume arm MAXAIR hanging model wall or post with exhaust fan and support bracket MAXAIR hanging model with...

Страница 17: ...et e 6 2 Boulon 0 25 x 0 75 7 1 Support de ressort de douille 2 trous MAXAIR hanging model wall or post with exhaust fan and support bracket MAXAIR hanging model wall or post with exhaust fan and supp...

Страница 18: ...ds and listen for grinding or unusual noise If fan runs smoothly you may start using the system Refer to MAXIDRIVE instruction manual if you need instructions 11 LIGHT KIT PARTS LIST AND INSTALLATION...

Страница 19: ...ECTRICIAN WIRING CF ORANGE CF YELLOW RED OL BROWN MTR1 OPTION CLASS 2 OPTION SXX OPTION FXX Adjust according to the table 1 VOLT Adjust according to the table 1 VOLT Adjust according to the table 1 OL...

Страница 20: ...e table 1 VOLT OPTION SXX OPTION FXX Adjust according to the table 1 OL Adjust according to the table 2 or 3 X1 X2 H1 H2 40VA 2 1 3 4 6 24VAC 5 U1 V1 L1 L2 Westburne Laval 3409 Boul Industriel 450 663...

Страница 21: ...r source capture Open and close air damper to ensure proper operation Move arm left and right Ensure no grinding or squeeking is heard or felt Weekly Flexible hoses Check for possible leaks or tears R...

Страница 22: ...bes for debris Open ductwork and check for debris Socket grinds squeaks jams Foreign object in socket Inspect complete socket assembly 24V LED light blinks Screws holding the bulb or bulb wiring in pl...

Страница 23: ...omer must notify Seller in writing of the Product defect which notice shall include a reasonable description of the defect within 10 days from the date such defect is discovered or ought to have been...

Страница 24: ...ty of such damages or could have reasonably foreseen them 16 3 Fire and Explosion and Acceptance of Risk Customer acknowledges that improper installation or use of the Product may result in fire or ex...

Отзывы: