POSITIVE clamp / ring connector to the positive battery terminal or vehicle chassis.
6) When disconnecting, disconnect in the reverse sequence, removing the negative first (or
positive first for positive ground systems).
7) Follow these steps when using 12V accessory plug: keep the vehicle hood open.
Connect the end of the 12V accessory plug to the charger; insert the 12V accessory plug
into the vehicle’s 12V outlet.
If the vehicle’s ignition key has to be on in order for the 12V
outlet to supply / receive power, turn the key, without starting the engine.
8) A marine (boat) battery must be removed and charged on shore. To charge it on board
requires equipment specially designed for marine use.
CHARGING MODES
AQ2000 has five modes:Standby,12V NORM, 12V COLD/AGM, 6V NORM and 12V
LITHIUM. Some charge modes must be held for three (3) seconds or / and pressed to enter
the mode. Do not operate the charger until you confirm the appropriate charge mode for
your battery.
Mode
Battery
Size (Ah)
Explanation
Standby
–––
Not charging or providing any power (Green LED)
12V NORM
2-60
Charging 12V WET/GEL/MF/EFB batteries (Blue
LED)
12V
COLD/AGM
2-60
Charging 12V batteries below 10
℃
(50℉) or 12V
AGM battery (Blue LED)
6V NORM
(Hold
Mode button for 3
seconds to enter)
2-60
Charging 6V WET/GEL/MF/EFB batteries (White
LED)
12V LITHIUM
(Hold & Press)
2-60
Charging 12V lithium-ion batteries only, including
LiFePO4 (Green LED)
These “Hold or / and Press” modes are advanced charging modes that require your
full attention before selecting.
Using 6V NORM (Hold)
This mode is designed for 6V lead-acid batteries only. Consult the battery manufacturer
before using this mode.
Using 12V LITHIUM (Hold & Press)