DIMENSIONS – X*TREME
®
-1
6 . SPECIFICATIONS
7 . TROUBLESHOOTING
1. Always ask and check the following:
A. Is the unit connected to a live power source?
B. Check the circuit breaker.
C. Is power switch on?
D. Is the unit operating on proper voltage?
2. If problems exist after checking the above, check the chart below.
3. If any service is needed (italicized items), call an APW Wyott authorized service agency. All service
should be performed by an APW Wyott authorized service agency.
PROBLEM
CAUSE
SOLUTION
Won’t toast...
a. Toaster cold.
a. Allow five (5) minutes for warm up.
b. Wrong power switch position.
b. Position power switch to full power.
c. Wrong conveyor speed setting.
c. Reduce conveyor speed.
Toasts unevenly...
d. Only part of product surface is toasted. d. Reduce conveyor speed.
e. Product located too far to side of conveyor. e. Place product on conveyor between end links.
Product sticks to conveyor or slide. f. Butter or butter substitute used on product. f. Discontinue use of butter or butter substitute.
g. Conveyor surface has baked-on oil residue. g. Follow daily cleaning methods to remove & prevent residue.
h. Very moist or doughy product.
h. Use different source or day old product.
i. Product not defrosted or thawed.
i. Defrost/thaw product.
No power...
j. No power to receptacle.
j. Check circuit breaker.
k. Toaster unplugged.
k. Plug in toaster.
l. Loose connections.
l. Check connections.
m. Power switch.
m. Check that switch is on & operational.
Won’t heat...
n. Loose connections.
n. Check connections.
o. Faulty power switch.
o. Replace power switch
p. Burnt out element.
p. Replace element.
Lighter toast under peak loads... q. Speed control setting.
q. Reduce speed control setting.
r. Very moist product.
r. Use different source or day old product.
s. Product too cold.
s. Allow product to warm to room temperature.
t. Toaster cavity temperature being quenched. t. Add 1” or more spacing between product.
Conveyor won’t move...
u. No power.
u. Check circuit breaker.
v. Conveyor links are binding.
v. Check conveyor for bent links.
w. Loose or bad connection between speed
control and conveyor motor.
w. Check for loose or bad connection.
x. Conveyor motor burnt out.
x. Replace conveyor motor.
y. Speed control burnt out.
y. Replace speed control.