4. OPERATION
Operating Instructions
Dry operation only
This toaster is for
(no oil). Do not put buttered bread products in the toaster.
Ensure Release sheets are properly installed. (See page 9.)
Turn Main Power Switch on. Set Temperature Control to desired temperature. (Temperature is factory
set at 600°F.) Allow Pilot Light to cycle at least two times (on/off). When the light is on, the grill is heating.
Heat up time is about 15 minutes.
Place bun halves on feeder cut side down (facing grill surface). Toast time is approximately 8, 20 or 30
seconds depending on bun height, diameter and model purchased. Increase or decrease temperature
setting to achieve desired brownness and temperature.
!!
!
OPERATION
1. When power is applied, the digital display will initially show the software version
then change to “Lo”.
2. Press appropriate UP or DOWN switch and then press and hold until desired
setpoint is displayed. Holding the UP or DOWN switch will cause the
setpoint to increment by 1 degree for the first 5 degrees and after that the display
will increment by 5 degrees at a time.
3. Heat On LED will be illuminated until temperature reaches setpoint. Once the
toaster reaches setpoint, the display will change to “rdy” and the Heat on LED will
turn off. The heat on LED will then cycle on and off to maintain temperature.
Bun ThicknessAdjustment
The VSX is designed to accommodate a variety of
different products. Adjust for product thickness by
setting the Bun Adjustment Knobs on the side of the
toaster to the appropriate setting. Settings for
different thicknesses are indicated on the label
adjacent to the adjusting knobs. See photo.
Temperature Control
DIGITAL DISPLAY:
UP SWITCH:
DOWN SWITCH:
HEAT ON LED:
MODE SWITCH:
Shows setpoint, actual
temperature and error / status
messages.
Increase / view setpoint.
Decrease / view setpoint.
Illuminated when power is
being applied to heater.
View actual temperature.
STATUS, ALARM, AND ERROR MESSAGES
Control has reached setpoint and the toaster is ready for operation.
Actual temperature is 50 degrees (or more) below setpoint.
Actual temperature is 50 degrees (or more) above setpoint.
Defective or disconnected temperature probe (sensor).
Appears if relay is defective or inoperable.
rdy
lo
Hi
Prb
HIE