APW Wyott SM-50-11DS Скачать руководство пользователя страница 6

2M-Z24236 Owners Manual for Built-In Round T’Stat W

armers

4

NOTE:

  DO NOT discard

the carton or other packing

materials until you have

inspected the appliance for

hidden damage and tested it 

for proper operation.

Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this

manual.

WARNING:

RISK OF  INJURY

Installation procedures must 

be performed by a qualified 

technician with full knowledge 

of all applicable electrical and 

plumbing codes.  Failure can 

result in personal injury and 

property damage.

CAUTION

FIRE HAZARD

Avoid storing flammable or 

combustible materials in, on

or near the appliance.

IMPORTANT:  

For warmers 

installed in plastic counter 

tops, the counter material 

must be protected from the 

heat of the warmer in order 

to prevent discoloration and/

or deterioration.  E-Z Lock are 

not suitable for this purpose.  

The installer should contact 

the manufacturer or distributor 

of the countertop material for 

specific instructions.  

IMPORTANT

:  E-Z Lock 

Extension Kits must be used 

ONLY with UL Listed warmers 

approved for installation in 

wood counter tops. Refer to 

the 

Installation Instructions

 

provided with the warmer.

UNPACKING & INSPECTION

Carefully remove the appliance from the carton.  Remove all 

protective plastic film, packing materials and accessories from the

Appliance before connecting electrical power or otherwise performing 

any installation procedure.
Carefully read all instructions in this manual and the 

Installation

Instruction Sheet

 packed with the appliance before starting any

installation.
Read and understand all labels and diagrams attached to the

appliance.
Carefully account for all components and accessories before

discarding packing materials.  Store all accessories in a convenient 

place for later use.

INSTALLATION NOTES

1.  Installation and start up of built-in warmers MUST be performed   

by an authorized installation company.

2.  It is the RESPONSIBILITY OF THE INSTALLER to verify that   

this warmer installation is in compliance with the specifications 

 

listed in this manual and on the specification sheet provided. 

3.  It is the RESPONSIBILITY OF THE INSTALLER to check with    

the AUTHORITY HAVING JURISDICTION, in order  to verify    

that this warmer installation is in compliance with local code  

 

requirements.

4.  Water supply and drain installation must meet all applicable     

local, state and federal plumbing codes and ordinances.

5.  Refer to Installation Instructions included with the warmer for                 

Underwriters Laboratories conditions of acceptability, electrical           

requirements and other installation concerns.

BUILT-IN WARMERS

1.  This is a GENERAL GUIDE.  For specific cutout dimensions  

 

and other installation details, refer to the Installation Instructions 

supplied with the warmer. 

2.  Cutout dimensions for warmer units and control panels are  

 

listed on the Installation Instructions provided with the warmer.

3.  Verify style of control panel (e.g oval, rectangular) before  

 

making cutout.

4.  Units that are being connected by a manifold system, all units MUST 

be installed on a level surface and with each other.  If the units are 

being installed on a mobile cart, the cart MUST be positioned on a 

level surface when put in use. 

NOTE:

  Cutout dimensions are different for insulated and non-insulated 

units, control panels, for UL LISTED units and UL Recognized units, 

and for wood and metal counters.  Verify the dimensions are correct for  

the installation before making the cutout.  Specific cutout specifications 

are list on the installation sheet included with the unit.
      

INSTALLATION

Содержание SM-50-11DS

Страница 1: ...l rights reserved This manual includes material related to installation use cleaning and care Exploded view s as well as any available parts list s and wiring diagram s pertaining to the unit s covere...

Страница 2: ...iness Hours 8 00 a m to 4 30 p m Central Telephone 800 264 7827 Tech Service Option 2 Email TechService partstown com www apwwyott com WARRANTY EXCLUSIONS THE FOLLOWING WILL NOT BE COVERED UNDER WARRA...

Страница 3: ...asing this APW Wyott appliance Proper installation professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical ser...

Страница 4: ...ial position is an indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built in warmers are be equipped...

Страница 5: ...er use is recommended or authorized by the manufacturer or its agents Operators of this appliance must be familiar with the appliance use limitations and associated restrictions Operating instructions...

Страница 6: ...s before discarding packing materials Store all accessories in a convenient place for later use INSTALLATION NOTES 1 Installation and start up of built in warmers MUST be performed by an authorized in...

Страница 7: ...ably decreased performance 2 Available electrical service amperage must meet or exceed the specifications listed on the specification sheet provided with the warmer 3 Warmer and control unit must be c...

Страница 8: ...not supplied by APW Wyott to be installed in order to operate correctly 5 For AUTOFILL units Some jurisdictions may require an approved back flow preventer in the water supply line It is the responsi...

Страница 9: ...e adding water 4 Damage caused by allowing a wet operation warmer to run dry is NOT covered by warranty Damage caused by adding water to a dry warmer when hot is NOT covered by warranty PRE HEATING TH...

Страница 10: ...ill lower the temperature of the food in the insert pan and may damage the warmer 3 Alternating between wet and dry operation in any individual warmer is NOT recommended 4 DO NOT use metal tools steel...

Страница 11: ...pans insets and other vessels are subject to a harsher environment APW Wyott Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless...

Страница 12: ...etergent cleanser residue 4 Inspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating e...

Страница 13: ...overs accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control...

Страница 14: ...yott Service Agency for repairs Warmer slow to heat Mineral deposits on pan acting as a insulator Clean pan s with delime cleaner Wired to wrong voltage Verify supply voltage must match voltage on war...

Страница 15: ...2M Z24236 Owners Manual for Built In Round T Stat Warmers 13 WIRING DIAGRAM...

Страница 16: ...rmers 14 EXPLODED VIEW PARTS LIST SM 50 7S and SM 50 11S with without Drain IL1904 Rev F 4 08 15 Model SM 50 4S SM 50 7S SM 50 11S w w o Drain SM 50 4ULS SM 50 7ULS SM 50 11ULS w w o Drain 1 2 22 3 4...

Страница 17: ...CONDUIT UNITS 11 WS 60282 THERMO CONTROL 1 SM 50 4S SM 50 4DS SM 50 7S SM 50 7DS SM 50 11S 12 P2 40843 THERMOSTAT MOUNTING BRKT 1 13 I7 Z12221 CONTROL PANEL 1 14 2J 35687 LIGHT SIGNAL 1 15 2R Z24181 C...

Страница 18: ...T w hinged lid 21057 E Z Lock EXTENSION KIT for UL LISTED circular warmers only adapt to wood counter up to 1 thick 22592 E Z Lock Extension Kits for UL Listed units approved for installation in wood...

Страница 19: ...2M Z24236 Owners Manual for Built In Round T Stat Warmers 17 NOTES...

Страница 20: ...65 Hobson St Smithville TN 37166 Telephone 800 527 2100 Printed in the U S A 2M Z24236 REV A 03 22 Specifications are subject to change without notice is a registered trademark of APW Wyott A Middleby...

Отзывы: