background image

l

Connect the regulator to the unit, connect gas and check for leaks. 

WARNING:

 Do not use an open 

flame to check for leaks. 

l

Check the system pressure. With the front panel removed remove the plug                                                

from the manifold.

l

Place a fitting in the plug opening and connect a manometer. 

l

For  Natural  gas  the  pressure  in  the  manifold  should  be  5”  water  column  or           

12.4 millibar. For LP the pressure in the manifold should be 10” water Column or 
24.9 millibar. 

l

To adjust the pressure remove the brass cap and turn the white plastic part inside 

the stem of the regulator. See picture regulator 8. 

l

Take a wide straight screw driver and place it in the two notches shown in picture regulator 7 turn 

clockwise to increase pressure and counter-clockwise to reduce pressure. See picture regulator 8. 

l

Once the pressure has been adjusted replace the brass cap. 

l

Note the blue cap on the regulator, this is the vent there are openings below the top rim. 

NEVER

 block 

these openings your regulator will fail to operate correctly. On at least a monthly basis blow off any dust 
or grease which may accumulate around this cap. The openings must remain open for the regulator to 
function. Clean more often in a very greasy atmosphere. 

8

NAT

LP

CONVERSION

l

Instructions are for conversion from Natural Gas to Propane (L.P.) on all models HMG.

l

The conversion should be done before connecting the unit to the gas supply.

l

Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP (propane) 
are provided in a bag tied to the valve on the front panel.

1. Remove the knobs and front panel.
2. Remove the orifice fittings from the valve. Change the orifices to the size recommended for 

propane (L.P.).

3. Replace the orifice fittings into the valve.

l

To change the regulator:

1. Remove brass 

cap

2. Locate the plastic 

part attached to the 
brass cap

3. This is the natural 

gas position

4. Snap the plastic 

part off of the brass 
cap

5. Flip the plastic part  

over & snap the        
plastic part onto the 
brass cap in the        
opposite direction

6. Note you can read 

LP on the plastic 
part it is now in the 
LP position

7. Replace the brass 

cap back into the 
body of the 
regulator

8. To adjust pressure:   

Remove brass cap &  
turn white plastic 
part inside the stem 
of regulator

Содержание HMG-2424

Страница 1: ...ther appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroug...

Страница 2: ...and liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles SeeANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in...

Страница 3: ...its operation is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manu...

Страница 4: ...connected Unit must have adequate clearances for servicing Sides 0 Rear 0 Floor 4 European Community Installation Instructions THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON IN THE UK CORGI REGIS...

Страница 5: ...MG 2436 36 914 4 38 09 967 5 15 460 392 7 3 32 000 9 78 96 000 28 1 5 12 4 HMG 2448 48 1219 2 38 48 977 4 15 460 392 7 4 32 000 9 78 128 000 37 5 5 12 4 HMG 2460 60 1524 0 38 09 967 5 15 460 392 7 5 3...

Страница 6: ...8 23 58 13 13 32 38 4 21 36 MANUAL GRIDDLE 32 92 6 27 38 48 48 0 45 000 15 46 13 13 32 38 4 61 23 58 33 88 48 MANUAL GRIDDLE 6 SPECIFICATIONS HEAVY DUTY GAS GRIDDLE HMG 2436 21826100 SPECIFICATIONS HE...

Страница 7: ...E HMG 2460 21826300 SPECIFICATIONS HEAVY DUTY GAS GRIDDLE HMG 2472 21826400 43 54 60 0 6 27 38 09 57 00 15 46 13 13 32 38 4 21 23 58 33 88 60 MANUAL GRIDDLE 44 92 72 0 6 27 38 21 69 00 15 46 33 88 13...

Страница 8: ...a monthly basis blow off any dust or grease which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere 8 NAT LP CONVE...

Страница 9: ...ilot valve more If the pilot flame appears larger than necessary turn it down and reset burner ignition The pilot flame should be as small as possible but large enough to guarantee reliable ignition o...

Страница 10: ...e in your area OPERATING INSTRUCTIONS Season Griddle Heat to low temperature 300 350 F 150 180C and pour on a small amount of cooking oil about one ounce 30cc per square foot of surface Spread the oil...

Страница 11: ...emoved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry c...

Страница 12: ...set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges or contains dark specks Heat is set too high...

Страница 13: ...ODY 36 FIREBOX 1 21826222 BODY 48 FIREBOX 1 21826322 BODY 60 FIREBOX 1 21826422 BODY 72 FIREBOX 1 4 21826017 SUPPORT BURNER 2 21826117 SUPPORT BURNER 2 21826217 SUPPORT BURNER 2 21826317 SUPPORT BURNE...

Страница 14: ...ACK 72 1 20 21826015 PANEL CONTROL 24 1 21826115 PANEL CONTROL 36 1 21826215 PANEL CONTROL 48 1 21826315 PANEL CONTROL 60 1 21826415 PANEL CONTROL 72 1 21 2065848 VENTURI HVY DTY GRIDDLES 2 3 4 5 6 22...

Страница 15: ...EBOX 1 21826236 BODY 48 FIREBOX 1 21826336 BODY 60 FIREBOX 1 21826436 BODY 72 FIREBOX 1 4 21826017 SUPPORT BURNER 2 21826117 SUPPORT BURNER 2 21826217 SUPPORT BURNER 2 21826317 SUPPORT BURNER 2 218264...

Страница 16: ...21826452 PANEL BACK 72 1 20 21826040 PANEL CONTROL 24 CE 1 21826140 PANEL CONTROL 36 CE 1 21826240 PANEL CONTROL 48 CE 1 21826340 PANEL CONTROL 60 CE 1 21826440 PANEL CONTROL 72 CE 1 21 2065849 VENTU...

Страница 17: ...45 20932101 NUT COMPRESSION FERRULE 2 3 4 5 6 46 21826016 BRACKET THERMOCOUPLE 2 3 4 5 6 47 21826046 TUBE PILOT SUPPLY CE 2 3 4 5 6 48 21826047 TUBE ORIFICE SUPPLY 2 3 4 5 6 49 8806070 LABEL DELIVERY...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ...f connection or use atAPWWyott soptionoritsAuthorizedServiceAgency itwillbeservicedonsiteorreplaced From day two through the conclusion of this warranty period portable units must be taken to or sent...

Страница 21: ...www apwwyott com Dallas Plant 729 Third Ave Dallas TX 75226 Local 1 214 421 7366 Toll Free 1 800 527 2100 Parts Service Fax 1 214 565 0976 Cheyenne Plant 1938 Wyott Drive Cheyenne WY 82007 Local 1 307...