background image

Installation and start-up should be performed by a qualified installer who thoroughly read, understands and

follows these instructions.

If you have questions concerning the installation, operation, maintenance or service of this product, write

Technical Service Department APW Wyott Foodservice Equipment Company, P.O. Box 1829, Cheyenne,

WY 82003.

Before installing and operating this equipment be sure everyone involved in its operation is fully trained and

is aware of all precautions. Accidents and problems can result by a failure to follow fundamental rules and

precautions.

The following words and symbols, found in this manual, alert you to hazards to the operator, service

personnel or the equipment. The words are defined as follows.

1. SAFETY PRECAUTIONS

Shut off gas flow through the appliance before cleaning or servicing unit.

!

!

WARNING:

This symbol refers to a potential hazard or unsafe practice, which could result

in serious injury or death.

!

!

DANGER:

This symbol warns of imminent hazard which will result in serious injury or

death.

!

!

CAUTION:

This symbol refers to a potential hazard or unsafe practice, which may result in

minor or moderate injury or product or property damage.

!

!

NOTICE:

This symbol refers to information that needs special attention or must be fully

understood even though not dangerous.

GENERAL INFORMATION

THIS MANUAL SHOULD BE RETAINED FOR FUTURE REFERENCE

CAUTION:

These models are designed, built, and sold for commercial use. If these

models are positioned so the general public can use the equipment, make sure that

cautions, warnings, and operating instructions are clearly posted near each unit so that

anyone using the equipment will use it correctly and not injure themselves or harm the

equipment.

!

!

!

!

WARNING:

A factory authorized agent should handle all maintenance and repair. Before

doing any maintenance or repair, contactAPW Wyott.

WARNING:

Install per the spacing requirements listed in the installation section of this

manual. We strongly recommend having a competent professional install the equipment.

A licensed electrician should make the electrical connections and connect power to the

unit. Local codes should always be used when connecting these units to electrical power.

In the absence of local codes, use the latest version of the National Electrical Code.

!

!

2

Содержание GGT-24H

Страница 1: ...tions Operation Instructions Maintenance Instructions Replacement Parts List Warranty Service Information Gas Griddles MODELS GGT 24H GGT 36H WITH SNAP ACTION THERMOSTAT WARNING Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment FOR Y...

Страница 2: ...his symbol refers to a potential hazard or unsafe practice which may result in minor or moderate injury or product or property damage NOTICE This symbol refers to information that needs special attention or must be fully understood even though not dangerous GENERAL INFORMATION THIS MANUAL SHOULD BE RETAINED FOR FUTURE REFERENCE CAUTION These models are designed built and sold for commercial use If...

Страница 3: ...nt Therefore installation should comply with all local codes WARNING A factory authorized agent should handle all maintenance and repair Before doing any maintenance or repair contact APW Wyott WARNING For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles SeeANZI Z83 14B 1991 NOT...

Страница 4: ...n inspection Be certain to hold all contents and packaging material Installation and start up should be performed by a qualified installer who thoroughly read understands and follows these instruction If you have questions concerning the installation operation maintenance or service of this product write Technical Service Department APW Wyott Foodservice Equipment Company P O Box 1829 Cheyenne 2 G...

Страница 5: ...urface Dimensions Width 23 13 16 605mm Depth 19 1 2 496mm NOTICE This appliance must be installed by a competent person in accordance with the rules in force In the U K Corgi registered installers including the regions of British Gas undertake to work to safe and satisfactory standards This appliance must be installed in accordance with the current Gas Safety Installation and Use Regulations and t...

Страница 6: ...rtment to escape 3 Depress red button on the pilot safety valve and light through observation hole in firebox Keep red button on pilot safety depressed for at least 1 minute after pilot has lit If pilot does not light repeat this step 4 To adjust the pilot flame rotate knob next to the red button Turning the knob clockwise increases the pilot flame Aproperly sized pilot should be 1 2 to 3 4 long 1...

Страница 7: ... s sides or back Avoid wall type fans which create air cross currents within the room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmosphere will occur adversely affecting operation and causing undesirable working conditions A properly designed and installed hood will act as...

Страница 8: ...Turn the manual shutoff valve to OFF field installed valve not supplied by the manufacturer turn all control knobs to the OFF position and shut off the pilot flame by turning the adjustment on the pilot valve If the griddle is to be shut down for an extended period put a heavy coat of grease over the griddle plate Service Repair NOTE THISAPPLIANCE MUST ONLYBE SERVICED BYANAUTHORIZEDAGENT NOTE If y...

Страница 9: ...Automatic pilot valve is bad Heat is set too high Moisture in the food may be turning into steam Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Heat is set too high Food m...

Страница 10: ...4 EXPLODED VIEW 10 64 1 2 3 5 4 6 7 8 9 10 11 12 13 14 15 16 17 18 20 22 23 24 25 26 27 28 29 30 32 33 34 35 37 38 36 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 8 PARTS LISTS EXPLODED VIEWS ...

Страница 11: ...3 8x3 8 BALL VALVE 3 4 THREADED ELBOW 3 8CC x 3 8 27 2 2 1 1 1 4 1 1 1 2 1 1 2 2 2 1 2 2 2 2 2 2 1 2 2 2 1 2 2 2 1 2 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 60 61 62 63 64 65 2092611 2066600 87056 20 8196602 81320 00 81300 00 81759 00 8170700 3100724 8507200 85093 00 8417100 84362 00 8196601 8837190 87055 17 21817770 8861000 8837129 8832600 8825300 8837120 438131...

Страница 12: ...GGT 36 EXPLODED VIEW 19 26 27 28 29 30 31 32 34 35 37 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 55 56 58 54 65 63 66 62 21 6 7 10 20 23 24 25 9 5 2 1 3 17 16 11 18 12 13 21 8 4 14 15 12 ...

Страница 13: ...27X44 BAG CLOTH 4 X6 W DRAWSTRING PLUG 1 8 NPTM DECAL OPER INSTR MANUAL GAS GRIDDLE BALL VALVE 3 4 THREADED ELBOW 3 8 C TO 3 8 NPT MALE 1 1 1 3 1 1 1 1 1 1 1 6 1 3 3 3 3 3 3 3 1 3 3 1 1 3 1 1 1 1 1 1 SIDE PANEL LH RH PANEL BACK FRONT PANEL LEG SUPPORT MANIFOLD WELDT WHG BURNER U HI PERFORMANCE WELDMENT GRIDDLE WHG T STAT MOUNT FIREBOX WELDT WHG BRACKET ORIFICE GREASE SLIDE GREASE DRAWER WELDMENT D...

Страница 14: ...Notes 14 ...

Страница 15: ...nd 2 toasters or rollergrills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply and problems due to ventilation Equipment that has not been properly maintained calibration of controls adjustments damage from improper cleaning and water damage to controls Equipment that has not b...

Страница 16: ...16 R APW WYOTT Foodservice Equipment Company P O Box 1829 Cheyenne WY 82003 1 307 634 5801 Phone 1 800 752 0863 Toll Free 1 307 637 8071 Fax ...

Отзывы: