background image

15 

GGT 

– PARTS LIST 

Item  P/N 

Description 

Quan 

Item 

P/N 

Description 

Quan 

218219-60 

Weldment, Griddle, GGT -18 

30* 

2300100 

Bags, Poly 36x27x44 

 

218220-60 

Weldment, Griddle, GGT -24 

32 

1018064 

Insulation, Thermostat Bulb 

 

218221-60 

Weldment, Griddle, GGT -36 

33 

8509300 

Washer, Flat, SAE, 5/16 

 

218222-60 

Weldment, Griddle, GGT -48 

34 

8436200 

Nut, Hex 5/16-18 S/S 

2092614 

Elbow, 3/8CC X 3/8NPT, No Hood 

Varies 

35 

8417100 

Nut, Hex, Keps 10-32 

81108-00 

M/S Tr Hd Ph 6-32 x 1" 

Varies 

36* 

2300000 

29x19x44 Poly 

2065614 

Valve, Pilot GGT-18 

37 

8170700 

Screw, 10-32x1/2, Type AB 

20 

 

2068001 

Pilot Valve GGT-24/36/48 

Varies 

38 

30047501 

Guide, Grease Slide 

22030005 

Support, Leg 18”, i-Line 

39 

8353000 

Pop Rivet 

 

22030010 

Support, Leg 24”, i-Line 

40 

8163100 

M/S Pn Hd Ph 10-32  X 1/4" 

 

22030015 

Support, Leg 36”, i-Line 

41 

8825300 

Decal, Leg 

 

22030020 

Support, Leg 48”, i-Line 

42 

8153100 

#8-32 X 3/8 Type T 

8400100 

Nut, Hex Keps, #6-32 

Varies 

43* 

8824518 

Decal, Dial Plate Thermostatic 

Griddle 

2092517 

Plug, 1/8 NPTM 

44 

8837190 

Tag, Orifice Location 

22031254 

Side Panel, LH 

45* 

8837201 

Bag, Cloth, 4"x6" W/Drawstring 

22031254 

Side Panel, RH 

46* 

8838800 

Manual, GGT-H/GGM-H 

Champion Ii

 

10 

21822047 

Tube, T-Stat/Hood Orifice 

GGT-24/36/48

 

Varies 

47* 

8899300 

List Of Service Agencies 

11 

21822034 

Bracket, Thermostat GGT 

Varies 

48 

2425400 

Pan, Grease 18" 

Varies 

12 

21821911 

Firebox, GGT -18 

 

2425500 

Pan, Grease 24" 

Varies 

 

21814020 

Firebox, GGT -24 

49 

2066154 

Pilot, Top GGT-18 

 

21822121 

Firebox, GGT -36 

 

2092800 

Pilot, Broiler GGT-24/36/48 

 

21814022 

Firebox, Ggt -48 

50 

8633700 

Leg, HD 2” Diameter W/Foot 

13 

21822035 

Bracket, Manifold GGT 

Varies 

51 

8196601 

Nut, U-Type 

14 

21822046 

Tube, T-Stat/Hood Orifice 

Varies 

52 

81973-00 

T/S #10 X ½ TPB Tr Hd 

15 

21821915 

Manifold, GGT-18H 

53 

43813149 

Label, Warning Hot Surface 
(French) 

 

21822029 

Manifold, GGT-24H 

Varies 

54 

21821920 

Bracket, Pilot Top T-Pile GGT-18 

 

21822130 

Manifold, GGT-36H 

 

21814036 

Bracket, Pilot GGT-24/36/48 

 

21822029 

Manifold, GGT-48H 

55 

8861000 

Label, Spec 

15* 

21821930 

Manifold, GGT-18H Pilot Safety 

56 

43813103 

Label, Warning, Hot Surface 

 

21822030 

Manifold, GGT-24H Pilot Safety 

57 

22031193 

Panel, Control GGT-18H 

 

21822035 

Manifold, GGT-36H Pilot Safety 

 

22031253 

Panel, Control GGT-24H 

 

21822235 

Manifold, GGT-48H Pilot Safety 

 

22031373 

Panel, Control GGT-36H 

16 

218207-16 

Side, Grease Chute 

 

22031493 

Panel, Control GGT-48H 

17 

2092506 

Elbow, 3/8C X 3/8 Ipt Male 

Varies 

58 

8706315 

Knob, GS-1A shaft metal set screw 

Varies 

18 

2069020 

Elbow, 1/8 Pipe To 3/8 Comp. 

Varies 

59 

2066850 

Orifice, #50 GGT-18 

Varies 

19 

2065855 

Burner, "S” GGT-18 

 

2066854 

Orifice, #54 GGT-24/36/48 

Varies 

19 

2065850 

Burner, "U” GGT-24/36/48 

Varies 

60 

2092904 

Orifice, Pilot L.P. GGT-24/36/48 

Varies 

20 

2092623 

3/8 Comp X 3/8 NPT Male Straight 

Varies 

61 

218208-26 

Logo, APWWYOTT Casted 

21 

2092903 

Pilot Nat @ 6" W.C. GGT-24/36/48 

63 

21821949 

Tube, Pilot Supply Standing GGT-

18 

22 

2067700 

Thermostat, Gas Snap Action 

Varies 

 

21822048 

Tube, Pilot Supply GGT-24/36/48 

Varies 

23 

21814019 

Bracket, Orifice 

64 

8837130 

Decal, Oper. Instr. 

24 

21821912 

Panel, Back GGT -18 

65 

8822325 

Decal, UL Sanitation, NSF Std. 4 

 

21822026 

Panel, Back GGT -24 

66 

8809920 

Decal, Improper Install 

 

21822127 

Panel, Back GGT -36 

67 

2092624 

3/8 Comp X 1/8 NPT Male Straight 

Varies 

 

21822228 

Panel, Back GGT -48 

68 

8837120 

Label, Orifice Size 

25 

21822045 

Tube, Manifold/T-Stat 

Varies 

69 

8832600 

Label, Service Hotline 

26 

21822044 

Tube, Manifold/T-Stat GGT-24/36/48 

 

 

*NOT SHOWN 

 

27 

2067300 

Regulator, Convertable 3/4 ½ PSIG 

 

 

 

 

28 

21723090 

Cover, Thermostat Bulb 

Varies 

 

 

 

 

29 

2066837 

Orifice, #37 GGT-18 

 

 

 

 

 

2066844 

Orifice, #44 GGT-24/36/48 

Varies 

 

 

 

 

Содержание GGM -24i

Страница 1: ... Parts this information is required Model Number Serial Number Date Purchased FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintai...

Страница 2: ...it s individual shutoff valve to be supplied by user must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa The appliance must be isolated from the gas supply piping system by closing it s individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or l...

Страница 3: ...its operation is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manual alert you to hazards to the operator service personnel or the equipment The words are defined as follows DANGER This symbol warns of imminent hazard which will result in serious injury or death WAR...

Страница 4: ...6 915 26 661 17 3 4 451 3 25 000 7 3 75 000 22 6 10 15 25 GGT 48i 48 1220 26 661 17 3 4 451 4 25 000 7 3 100 000 29 3 6 10 15 25 GGM 18i 18 457 26 661 17 3 4 451 1 37 500 11 37 500 11 6 10 15 25 GGM 24i 24 610 26 661 16 3 4 426 2 25 000 7 3 50 000 14 6 6 10 15 25 GGM 36i 36 915 26 661 16 3 4 426 3 25 000 7 3 75 000 22 6 10 15 25 GGM 48i 48 1220 26 661 16 3 4 426 4 25 000 7 3 100 000 29 3 6 10 15 2...

Страница 5: ... 5440 PART 2 BS 6891 THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE MUST BE INSTALLED IN A WELL VENTILATED AREA Ventilation requirements ie B S 5440 LIGHTING INSTRUCTIONS GGT and GGM Griddles are furnished with either a pilot safety valve or a standing pilot not available in the European Community Please follow the instructions for your unit Pilot Safety Valve Lighting Inst...

Страница 6: ...he unit Wherever possible avoid open windows next to the units sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmospheric pressure will occur which will effect operation and cause undesirable worki...

Страница 7: ...t may be used on the plate surface to help clean it but care must be taken to be sure the detergent is thoroughly removed After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry cloth To remove discoloration use a nonabrasive cleaner After each weekly cleaning the...

Страница 8: ...es to the size recommended for propane L P For units with a pilot safety valve you must also change the pilot orifice to the other pilot orifice supplied 4 Replace the orifice fittings into the valve 5 Replace the front panel and knobs 6 Before installing the regulator unscrew the octagonal cap With the brass portion of the cap up you can read NAT on the plastic insert Snap the insert out of the c...

Страница 9: ... 10 to the right and for the 48 GGT repeat this twice more 10 to the right always remaining 10 5 8 from the splash guard After all locations are marked center the temperature probe on each marked location and then trace a circle around the probe This procedure will place the temperature probe over the center of each thermostat bulb and this is the only place temperature readings should be taken Se...

Страница 10: ...crease the temperature approximately 24ºF turn counterclockwise will increase the temperature approximately 24ºF Adjust and re measure the average temperature until you get the temperature to your desired point NOTE avoid making more than turn at a time Calibration is not linear and you can get the thermostat significantly out of calibration to a point where it is difficult to reset If after adjus...

Страница 11: ...ning into steam Food sticks to griddle Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges or contains dark specks Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food is undercooked inside Heat is s...

Страница 12: ...12 PARTS LISTS EXPLODED VIEWS GGM GRIDDLES EXPLODED VIEW ...

Страница 13: ...210 17 Support Burner 48 2 39 8837129 Label Instr location 1 11 2066844 Orfice 44 Varies 40 8832600 Label Service Hotline 1 12 8417100 Nut Hex KEPS 10 32 Varies 41 8837130 Decal Oper Instr 1 13 2065643 Valve Pilot 90 1 8NPT X 3 16CC GGM 18 Varies 42 2067300 Regulator Convertible 3 4 PSIG 1 2068001 Pilot Valve GGM 24 36 48 Varies 43 8809920 Decal Improper Install 1 14 21813075 Burner S 1 44 8825300...

Страница 14: ...14 GGT GRIDDLES EXPLODED VIEW ...

Страница 15: ...00 T S 10 X TPB Tr Hd 4 15 21821915 Manifold GGT 18H 1 53 43813149 Label Warning Hot Surface French 1 21822029 Manifold GGT 24H Varies 54 21821920 Bracket Pilot Top T Pile GGT 18 1 21822130 Manifold GGT 36H 1 21814036 Bracket Pilot GGT 24 36 48 1 21822029 Manifold GGT 48H 1 55 8861000 Label Spec 1 15 21821930 Manifold GGT 18H Pilot Safety 1 56 43813103 Label Warning Hot Surface 1 21822030 Manifold...

Страница 16: ... Wyott s option or its Authorized Service Agency it will be serviced on site or replaced From day two through the conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on portable units after the first day of use If the customer wants on site service they may rec...

Отзывы: