Cleaning should be done Daily.

DO NOT USE ANY

Always ask and check the following:

1.

Remove door by pulling it, in an upward direction. Start the lifting motion with the door in the open

position.

2.

In order to effectively clean the interior of the unit, you will need to remove all four “Corner Rack

Supports”, which are fastened with 2 thumbscrews each.

3.

To remove the “Corner Rack Supports” (Item B in Fig.1), turn the thumbscrews in a counter-

clockwise direction. Repeat the process for all four “Corner Rack Supports”. Note that each “Corner

Rack Support” is fastened by two thumb screws which are shown by (ItemAin Fig.1)

4.

Clean with warm soapy water and a soft cloth only.

5.

ammonia, alcohol, or chlorine type cleaner will cause cracking of the enclosure

and door(s).

6.

Once the interior of the cabinet, along with “Corner Rack Supports” have been cleaned in the

fashion described above, re-install all four of them using the thumbscrews provided with the unit.

1.

Is the unit connected to a live power source of the proper voltage?

2.

Check the circuit breaker.

3.

Is power switch “ON” and light glowing?

4.

Check the rating label. Is the unit connected to the correct power source?

5.

If the above checks out, and you still have problems, call anAPW Wyott authorized service agent.

TROUBLESHOOTING

1

77612021

TOP

1

2

77612012

TOP SUB ASSEMBLY

1

3

85830

HEATING ELEMENT

1

4

69127

HIGH-LIMIT SAFETY SWITCH

1

5

85836

BLOWER MOTOR / FAN ASSEMBLY

1

6

75916

LAMP, 40 W, COATED

1

7

46879

LAMP SOCKET

1

8

66725

LIGHT GUARD WIRE RACK

1

9

88890

THUMBSCREW FOR LIGHT

1

10

69128

THERMOMETER

1

11

77612027

PLASTIC DOOR

1

12

77612026

DISPLAY RACK

2

13

89408

MAIN SWITCH, LIGHT ROCKER

1

14

89101

STRAIN RELIEF BUSHING

1

15

55947

POWER CORDSET

1

16

69155

TEMPERATURE CONTROL THERMOSTAT

1

17

89499

INDICATOR KNOB

1

18

77612033

CORNER RACK SUPPORT

4

19

77612041

THUMB SCREW FOR RACK SUPPORTS

8

ITEM PART NUMBER

DESCRIPTION

QUANTITY

REPLACEMENT PARTS LIST - DWC-17 WARMING CABINET

Содержание DWC-17

Страница 1: ...eered to provide you with year round dependable service when used according to the instructions in this manual and standard commercial kitchen practices WARNING Improper installation adjustment altera...

Страница 2: ...NOT CLEAN UNIT WITH A WATER JET Always clean equipment before first use Check the rating label for your model designation and electrical rating Rating Label is located on the inside frame of the unit...

Страница 3: ...l objects from the warmer Use Utensils to remove Product NOTE Should the temperature setting be changed allow several minutes for the temperature to adjust Once the desired setting has been achieved n...

Страница 4: ...above re install all four of them using the thumbscrews provided with the unit 1 Is the unit connected to a live power source of the proper voltage 2 Check the circuit breaker 3 Is power switch ON an...

Страница 5: ...5 EXPLODED VIEW DWC 17 WARMING CABINET 17 18 13 14 11 11 16 15 19 12 5 4 3 1 2 6 10 9 7 8...

Страница 6: ...rectory find the service agency nearest you call the number listed or the 24 hour toll free service hot line 1 800 733 2203 If there is not a service agency listed for your area the parts distributor...

Страница 7: ...2 toasters or rollergrills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply an...

Страница 8: ...8 APW WYOTT 729 Third Avenue Dallas TX 75226 Phone 1 Fax 1 214 565 0976 Toll Free 1 800 527 2100 Website www apwwyott com E mail info apwwyott com 214 421 7366 R...

Отзывы: