APW Wyott COLDWELLS CW-13 Скачать руководство пользователя страница 3

3

LOCATION OF DATAPLATE:

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE

The data plate for the Coldwell is located on the compressor housing above the power switch.

All containers should be examined for damage before and during unloading. The freight carrier has

assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent

or concealed, a claim must be made with the delivering carrier.

A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed

by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carrier can

supply the necessary forms.

B) Concealed damage or loss if not apparent until after equipment is uncrated, a request for inspection

must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to hold all

contents and packaging material.

Installation and start-up should be performed by a qualified installer who thoroughly read, understands and

follows these instructions.

CONTENTS

Safety Precautions

2

4
4

Parts List & Exploded View

7

Warranty

8

Specifications

4

Installation
Electrical Connections
Wiring Diagram

5

Operating Instructions

5

Maintenance

6

General Troubleshooting

6

!

!

CAUTION: Maintenance & repair should be handled by a factory authorized agent. Before doing

any maintenanceor repair, contactAPW Wyott.

WARNING: Install per the spacing requirements listed in the installation section of this manual. We

strongly recommend having a competent professional install the equipment.A licensed electrician

should make the electrical connections and connect power to the unit. Local codes should always

be used when connecting these units to electrical power. In the absence of local codes, use the

latest version of the National Electrical Code.

!

!

!

!

WARNING:

-

SHOCK HAZARD Do not open any panels that require the use of tools.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause

property damage, injury or death. Read the Installation, Operating and Maintenance Instructions

thoroughlybefore installing or servicing this equipment.

!

!

!

!

WARNING: Never clean any electrical unit by immersing it in water. Turn off before cleaning
surface.

!

!

WARNING:

-

SHOCK HAZARD

De-energize all power to equipment before cleaning the

equipment.

!

!

WARNING: Appliance must be connected by an earthing cable to all other units in the complete
installation and thence to an independentearth connection.

Get user manuals: 

See SafeManuals.com

 

 

Содержание COLDWELLS CW-13

Страница 1: ...ng to the instructions in this manual and standard commercial kitchen practices WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the Installation Operating and Maintenance Instructions thoroughly before installing or servicing this equipment R IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this man...

Страница 2: ...ositioned so the general public can use the equipment make sure that cautions warnings and operating instructions are clearly posted near each unit so that anyone using the equipment will useitcorrectlyandnotinjurethemselvesorharmtheequipment WARNING Improper installation adjustment alteration service or maintenance can cause propertydamage injuryordeath ReadtheInstallation OperatingandMaintenance...

Страница 3: ...cifications 4 Installation Electrical Connections Wiring Diagram 5 Operating Instructions 5 Maintenance 6 General Troubleshooting 6 CAUTION Maintenance repair should be handled by a factory authorized agent Before doing anymaintenanceorrepair contactAPWWyott WARNING Installperthespacingrequirementslistedintheinstallationsectionofthismanual We stronglyrecommendhavinga competentprofessionalinstall t...

Страница 4: ...nstalled theplugforthisunitshouldbeaccessible WARNING Checkthedataplateonthisunitbeforeinstallation Connecttheunitonlytothevoltage andfrequencylistedonthedataplate Connectonlyto1or3phaseaslistedonthedataplate CAUTION Ifthepowercordisdamaged replaceonlywithanidenticalpowercord WARNING IMPROPER GROUNDING COULD RESULT IN ELECTRICAL SHOCK This appliance is equipped with a three prong grounded plug for...

Страница 5: ...arm adjust the thermostat The thermostat adjustment is located above the power switch on the compressor housing To access the thermostat adjustment remove the hole cover to reveal the flat screw driver adjust shaft Turning the screw 1 4 turn clockwise will lower the temperature approximately 6 F Conversely turning the screw 1 4 turn counterclockwise will raise the temperature 5 F If you are unable...

Страница 6: ...on abrasive cleaner only soap and water recommended NEVER USE NEVER NEVER WARNING SHOCK HAZARD De energize all power to equipment before cleaning the equipment GENERAL TROUBLESHOOTING If the unit fails to operate check the following 1 Make sure the unit connected to a live power source 2 Check the circuit breaker to be sure it has not been tripped 3 Check if the power switch is on and the indicato...

Страница 7: ...r 18125 00 18125 00 6 Thermostat 14894 00 14894 00 7 Compressor Housing 217708 10 217708 10 8 Power Switch 13056 10 13056 10 9 Cordset 16 3 15067 00 15066 00 10 Strain Relief 89680 00 89680 00 11 Bracket Motor Not Shown 12001 00 12001 00 12 Hole Plug Not Shown 16218 00 16218 00 ITEM DESCRIPTION CW 13 120V 60Hz CW 13 220V 50Hz COLDWELL CW 13 7 Get user manuals See SafeManuals com ...

Страница 8: ...lergrills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply and problems due to ventilation Equipment that has not been properly maintained calibration of controls adjustments damage from improper cleaning and water damage to controls Equipment that has not been used in an appro...

Отзывы: