Caution:
DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and
water solution before operating unit.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.
Noncombustible clearances:
0" sides (0 mm)
0" rear (0 mm)
4” floor (102mm)
Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the
flue.
Adequate clearance for air openings into the combustion chamber is required. Do not place objects
between the bottom of the unit and the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the burners are
removable thru the front if the gas line is disconnected.
European Community Installation Instructions:
“THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI REGISTERED
INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND
SATISFACTORY STANDARDS. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE
GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING
REGULATIONS / I
EE.
REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE
FOLLOWING BRITISH STANDARD CODES OF PRACTICE - BS 6172, BS 5440 PART 2, BS 6891"
"THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE”
"MUST BE INSTALLED IN A WELL VENTILATED AREA. Ventilation requirements ie. B.S. 5440."
LIGHTING INSTRUCTIONS
GGT and GGM Griddles are furnished with either a pilot safety valve or a standing pilot (not available in the
European Community). Please follow the instructions for your unit.
Pilot Safety Valve Lighting Instructions
1.
Turn on main gas supply to unit, on-off valve located behind the unit (not supplied with unit).
2.
Turn the burner control knobs to "OFF" position. Wait at least 5 minutes to allow any gas which may
have accumulated in the firebox compartment to escape.
3.
Through the hole in the front panel, press red button on the pilot safety valve and light through
observation hole in firebox. Keep red button on pilot safety depressed for at least 1 minute after pilot
has lit. If pilot does not light, repeat this step.
Standing Pilot Lighting Instructions
( Not Available in the European Community )
The pilot lights on the griddles have been set at the factory. A screwdriver maybe required for the first lighting
to adjust the flame for your elevation.
1.
Turn off the manual shut off valve and wait 5 minutes to clear the gas.
2.
Turn all knobs to the "OFF" position.
3.
Turn the manual shut off valve on.
4.
Hold an ignition source (match) at the pilot. When the flame is established, remove the ignition
source.
5