background image

R

APW WYOTT Foodservice Equipment Company

P.O. Box 1829

Cheyenne, WY 82003

+1 (307) 634-5801  Phone                                                                                +1 (800) 752-0863  Toll Free
+1 (307) 637-8071  Fax                                                                                                www.apwwyott.com

INSTALLATION 

AND 

OPERATING 

INSTRUCTIONS

  P/N 8838800 4-08

 

 

 

 

IMPORTANT FOR FUTURE REFERENCE

 

Please complete this information and retain this manual for the life of the equipment. For 
Warranty Service and/or Parts, this information is required.

         Model Number                         Serial Number                              Date Purchased

 

Gas Griddles

MODELS: GGT-18H, -24H, -36H, -48H

&

MODELS: GGM-18H, -24H, -36H, 48H

 

 

 

 

 

 

 

WARNING:

 Improper installation, operation, service or maintenance can cause property 

damage,  injury  or  death.    Read  and  understand  these  instructions  thoroughly  before 
positioning, installing, maintaining or servicing this equipment.

!

!

 

FOR YOUR  SAFETY:

  Do  not  store  or  use  gasoline  or  other  flammable  vapors  and 

liquids in the vicinity of this or any other appliance.

!

!

1

 

 

 

(US & Canadian units are convertible and are assembled for Natural Gas)

(European units are not convertible and assembled for the appropriate gas)

Содержание Champion GGM-18H

Страница 1: ...umber Serial Number Date Purchased Gas Griddles MODELS GGT 18H 24H 36H 48H MODELS GGM 18H 24H 36H 48H WARNING Improper installation operation service or maintenance can cause property damage injury or...

Страница 2: ...al shutoff valve to be supplied by user must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa The appliance must...

Страница 3: ...result in serious injury or death DANGER This symbol warns of imminent hazard which will result in serious injury or death CAUTION This symbol refers to a potential hazard or unsafe practice which ma...

Страница 4: ...GM 36 36 915 26 661 16 3 4 426 3 25 000 7 3 75 000 22 6 10 15 25 GGM 48 48 1220 26 661 16 3 4 426 4 25 000 7 3 100 000 29 3 6 10 15 25 MODEL WIDTH IN MM DEPTH IN MM HEIGHT IN MM OF BURNERS BTU kW PER...

Страница 5: ...BS 5440 PART2 BS 6891 THISAPPLIANCE MUSTBE INSTALLED INACCORDANCE WITHTHE RULES IN FORCE MUSTBE INSTALLED INAWELLVENTILATEDAREA Ventilation requirements ie B S 5440 LIGHTING INSTRUCTIONS GGT and GGM G...

Страница 6: ...e unit Wherever possible avoid open windows next to the units sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowe...

Страница 7: ...cleaning the griddle must be seasoned again If the griddle usage is very high the weekly cleaning procedures may be done more often than once a week Extended Shutdown Turn the manual shutoff valve to...

Страница 8: ...size recommended for propane L P For units with a pilot safety valve you must also change the pilot orifice to the other pilot orifice supplied GGT Models GGM Models 4 Replace the orifice fittings int...

Страница 9: ...next thermostat bulb For a 36 GGT repeat this one more time 10 to the right and for the 48 GGT repeat this twice more 10 to the right always remaining 10 5 8 from the splash guard After all locations...

Страница 10: ...ded by two equals the average temperature EXAMPLE Flame extinguished 367 F Flame ignition 341 F 708 2 Average temperature 354 F If the average temperature is within 15 F of the dial marking you probab...

Страница 11: ...set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges or Heat is set too high contains dark specks...

Страница 12: ...12 PARTS LISTS EXPLODED VIEWS GGM GRIDDLES EXPLODED VIEW 40 22 16 17 18 5 7 8 11 21 41 32 42 23 33 43 24 44 15 25 35 45 26 36 37 48 49 20 30 50 39 2 4 34 38 3 19 29 28 27 56 12 9 10 14 46 47 1 6 31 13...

Страница 13: ...218209 18 218210 18 Weldment Griddle GGM 18 Weldment Griddle GGM 24 Weldment Griddle GGM 36 Weldment Griddle GGM 48 Body 18 Firebox GGM Body 24 Firebox GGM Body 36 Firebox GGM Body 48 Firebox GGM Tub...

Страница 14: ...17 42 44 67 48 1 38 28 GGT GRIDDLES EXPLODED VIEW 53 51 59 69 66 40 60 12 22 16 18 5 7 8 9 10 11 21 41 32 23 33 58 68 14 24 52 15 25 35 26 55 65 37 57 61 49 20 50 39 2 4 54 64 62 34 6 3 13 19 63 29 27...

Страница 15: ...es 1 Varies 2 2 2 2 Varies 1 1 1 Varies Varies 1 1 1 1 Varies Varies 1 Varies 1 1 1 1 1 1 2 Varies Varies 1 Varies Varies 1 Varies 2 1 1 1 1 Varies 1 1 Varies 1 Varies Bags Poly 36x27x44 Insulation Th...

Страница 16: ...onclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott AuthorizedServiceAgency for in warrantyrepairs No mileageor travelcharges areallowedon portableunits...

Отзывы: